What are the repair parts for the EZM31200FSE, Series M03 main circuit breaker unit?
Issue:
Design repair parts
Product Line:
EZM Metering Equipment
Environment:
repair parts
Cause:
Maintenance
Resolution:
Only the parts listed below are considered field replaceable:
Top Cover - EZM31200FSETC (the top cover includes the handles, breaker box/cover and all appropriate labels)
Bottom Cover - MTR10291 (the bottom cover includes the handles)
Main Molded Case Switch - PJF36000S12
Cover Screws - 4020513002K (This is a pack of 10 screws)
Cover Sealing Screw - X1299 (Top cover requires 2 and the bottom cover requires 2)
Bonding Strap Kit - 7329696759
Mounting Channel - 7329354306
End Closing Cap Kit - EZMCAP
End Closing Cap Kit (Right Side Only Shallow) - EZMSCAP
VISI-TITE NUT/WASHER - 7329697350 (this is the Double Deaded nut with the RED disc, that is used to tighten the Main Horizontal Cross Bus together)
Bottom Endwall Blank Piece - 7329386565
Bottom endwall blank piece mounting screws - 2142217101 (6 required)
Sealing wing nuts for End Closing Caps - 7329697250 (This kit contains 4 wing nuts and the EZM installation instructions)
Design repair parts
Product Line:
EZM Metering Equipment
Environment:
repair parts
Cause:
Maintenance
Resolution:
Only the parts listed below are considered field replaceable:
Top Cover - EZM31200FSETC (the top cover includes the handles, breaker box/cover and all appropriate labels)
Bottom Cover - MTR10291 (the bottom cover includes the handles)
Main Molded Case Switch - PJF36000S12
Cover Screws - 4020513002K (This is a pack of 10 screws)
Cover Sealing Screw - X1299 (Top cover requires 2 and the bottom cover requires 2)
Bonding Strap Kit - 7329696759
Mounting Channel - 7329354306
End Closing Cap Kit - EZMCAP
End Closing Cap Kit (Right Side Only Shallow) - EZMSCAP
VISI-TITE NUT/WASHER - 7329697350 (this is the Double Deaded nut with the RED disc, that is used to tighten the Main Horizontal Cross Bus together)
Bottom Endwall Blank Piece - 7329386565
Bottom endwall blank piece mounting screws - 2142217101 (6 required)
Sealing wing nuts for End Closing Caps - 7329697250 (This kit contains 4 wing nuts and the EZM installation instructions)
Released for: Schneider Electric USA
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.