How can we help you today?

How do I program the ATV320 for remote HMI control?

Issue:
Programming the ATV320 for remote HMI control.

Product line:
ATV320, ATV31 , ATV312

Environment:
All serial numbers

Cause:
Customer would like to control with VW3A1101

Resolution:
Set Ref 1B switching to Ref 1 ch
Set Ref 1 ch to HMI
Set Porfile (CHCF)  to SEP
Set Cmd switching (CCS) to Cd1
Set Cmd cd1 to HMI

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Help and Contact Center
  • Contact Sales
  • Find our Offices
  • Where to Buy
  • Tech Support: 877-342-5173
  • Careers
  • Company Profile
  • Investors
  • Newsroom
  • Report a Misconduct
  • Product Documentation
  • Software and Firmware
  • Product Selector
  • Product Replacement
  • DigestPLUS Online Catalogue
  • Blog
  • Events
  • Schneider Electric Community
  • Sustainability
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings