How can we help you today?

Does the power distribution block design of the Energy Center still have lug connections for connecting both top and bottom connections to the backup circuit?

Issue:
Does the power distribution block design of the Energy Center still have lug connections for connecting both top and bottom connections to the backup circuit?

Product Line:
Energy Center

Resolution:
The PDB has multiple lug connections per phase at its output. These are intended to allow either one or both submain breakers to be connected to power via an internal or external backup interface for grid isolation during backup mode. One breaker is connected this way from the factory to produce partial home backup. The other breaker can also be connected there to give whole house backup.

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Help and Contact Center
  • Contact Sales
  • Find our Offices
  • Where to Buy
  • Tech Support: 877-342-5173
  • Careers
  • Company Profile
  • Investors
  • Newsroom
  • Report a Misconduct
  • Product Documentation
  • Software and Firmware
  • Product Selector
  • Product Replacement
  • DigestPLUS Online Catalogue
  • Blog
  • Events
  • Schneider Electric Community
  • Sustainability
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings