How is the LED indication reset on an AF or AFGF circuit breaker?
Issue:
How is the LED indication reset on an AF or AFGF circuit breaker?

Product Line:
QO and HOM arc fault and dual function breakers

Resolution:
In order to clear the LED indicator, run the time saver diagnostic (TSD) sequence 6 times.
On the 7th TSD attempt, the circuit breaker will trip after 5 seconds and the LED indicator will clear.
Note: If the LED light pulses 7 times, contact a certified electrician to replace the circuit breaker.