PoE Rackmount Surge Protector

Form Type - PoE Rackmount Surge Protector

Issue: What is the right part number for a PoE Rackmount Surge Protector

Product Line: ASCO Surge Protection Device (SPD's)

Environment:  Data Center. Rackmount.  SPD.

Resolution – How to order. Order the chassis with 8-ports and add extra modules as needed.


Regarding the 186 Series and the orderable part numbers, you will now just order the base chassis with 8 ports x # of modules needed (8 ports each) and based on the total number of ports needed.

·        Qty 1     - Base chassis with 8 ports included Part# 186D068S10KX08N0 (can add up to 5 modules - (8 port modules for a total of 48 ports))

·        Qty ___ - 8 port modules Part# RMCAT6MOD1  (Old: RM-CAT6-MOD1 8 port module / New: RMCAT6MOD1)


Select total ports needed:

Legacy P/N - RM-CAT6-8POE
Qty 1 chassis 8 ports included  (8x1=8) 186D068S10KX08N0

No additional modules  (8x0=0)

8 ports total

Legacy P/N - RM-CAT6-16POE
Qty 1 chassis 8 ports included  (8x1=8) 186D068S10KX08N0

Qty 1 8 port modules (8x1=8)  RMCAT6MOD1

16 ports total

Legacy P/N - RM-CAT6-24POE
Qty 1 chassis 8 ports included  (8x1=8) 186D068S10KX08N0

Qty 2 8 port modules (8x2=16) RMCAT6MOD1

24 ports total

Legacy P/N - RM-CAT6-32POE
Qty 1 chassis 8 ports included  (8x1=8) 186D068S10KX08N0

Qty 3 8 port modules (8x3=24)  RMCAT6MOD1

32 ports total

Legacy P/N - RM-CAT6-40POE
Qty 1 chassis 8 ports included  (8x1=8) 186D068S10KX08N0

Qty 4 8 port modules (8x4=32)  RMCAT6MOD1

40 ports total

Legacy P/N - RM-CAT6-48POE
Qty 1 chassis 8 ports included  (8x1=8) 186D068S10KX08N0

Qty 5 8 port modules (8x5=40)  RMCAT6MOD1

48 ports total

ASCO 186 Series Product Information: https://www.se.com/us/en/product-range/66218-asco-186-(edco-rm-cat6-poe)-surge-protective-device/#overview

186 IO https://www.se.com/us/en/download/document/SPD-UM-SPIOMM160186247/

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:

Need help?

Need help?

Product Selector

Product Selector

Quickly and easily find the right products and accessories for your applications.

Get a Quote

Get a Quote

Start your sales inquiry online and an expert will connect with you.

Where to buy?

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Help Center

Help Center

Find support resources for all your needs, in one place.

  • Help and Contact Center
  • Contact Sales
  • Find our Offices
  • Where to Buy
  • Tech Support: 877-342-5173
  • Careers
  • Company Profile
  • Investors
  • Newsroom
  • Report a Misconduct
  • Product Documentation
  • Software and Firmware
  • Product Selector
  • Product Replacement
  • DigestPLUS Online Catalogue
  • Blog
  • Events
  • Schneider Electric Community
  • Sustainability
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings