How can we help you today?

Can multiple users concurrently connect to a separate instance of Control Expert that is installed on a remote PC..

Yes, it is possible if the PC has a floating license provided that the following conditions are met.
  • The Enterprise License Server must be installed on a Windows server operating system.  A desktop standard Windows operating system cannot be used.
  • On a server operating system several usage rights of a floating license for Control Expert must be activated, making this server the Enterprise License Server (ELS)
  • On the same server operating system several sessions (with individual login) can run in parallel, at the same time.
  • In each such session a separate instance of Control Expert is running will consume one usage right of the floating license for Control Expert hosted on the ELS
  • Each of those instance can be connected to from remote PCs via a terminal session.

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Help and Contact Center
  • Contact Sales
  • Find our Offices
  • Where to Buy
  • Tech Support: 877-342-5173
  • Careers
  • Company Profile
  • Investors
  • Newsroom
  • Report a Misconduct
  • Product Documentation
  • Software and Firmware
  • Product Selector
  • Product Replacement
  • DigestPLUS Online Catalogue
  • Blog
  • Events
  • Schneider Electric Community
  • Sustainability
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings