How can we help you today?

VMware host fail to enter maintenance mode due to powered on VM/s.

Issue:
If there are duplicate VMs with the same hostname, such as "localhost," this can sometimes result in VMs being incorrectly identified as system VMs and skipped for shutdown, which prevents hosts from entering maintenance mode.

Product:
PowerChute Network Shutdown

Environment:
VMware vCenter Server and ESXi hosts

Cause:
Duplicate VMs with the same hostname assigned.

Solution:
Ensure that all VMs are correctly configured with a unique hostname.

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Help Center
  • Contact Sales
  • Find our Offices
  • Where to Buy
  • Tech Support: 877-342-5173
  • Careers
  • Company Profile
  • Investors
  • Newsroom
  • Report a Misconduct
  • Product Documentation
  • Software and Firmware
  • Product Selector
  • Product Replacement
  • DigestPLUS Online Catalog
  • Industries
  • Partners
  • Schneider Electric Community
  • Events
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings