Fast
Shorter equipment lead times and faster project turnaround
Easy
Estimating and bidding is easier and less of a hassle
Flexible
Keep crews productive with on demand, factory-approved for-construction drawings
-
Ratings & Options
- Ratings:
up to 4000 A and 100 kAIC with Bus Bar Plating
- Design voltage:
up to 600 Vac or 250 Vdc
- Available Enclosures:
Indoor NEMA 1 or Outdoor NEMA 3R
- Bussing options:
Aluminum with tin plating or Copper with silver plating
- Single or double row I-Line™ distribution configuration
- Powerlogic™ power meters
PM8000 series, ION7550/ION7650 series, ION 9000 series
- Internally mounted Surgelogic® surge protective devices
- Group-mounted and Individually mounted devices
with metering down to 15 A and Energy Reduction Maintenance Switch (ERMS)
- Ratings:
-
Ratings & Options
- General:
Panels over transformer configurations
Pre-wired and factory installed power cables
Top and bottom conduit entry/exit space available
Freestanding construction
Front and rear aligned sections
NEMA 1 and Seismic Qualified IBC/ASCE7
- NF Panel:
Source type: single main or main lug
UL® Service Entrance Label
Max available fault current (RMS): 14kA through 65kA
System protection: fully or series rated
System ampacity: 175 A through 400 A
Circuit counts of 18, 30, 42, 54
Bus metal and plating: AL Tin / CU Tin or Silver
Solid neutral: AL or CU, 100% Rated
Incoming lug types: AL mechanical lug
Device lock options
- NQ Panel:
Source type: single main or main lug
Max available fault current (RMS): 10kA through 22kA
System protection: fully or series rated
System ampacity: 50 A through 400 A
Circuit counts of 18, 30, 42, 54, 72, 84
Bus metal and plating: AL Tin / CU Tin, Silver
Solid neutral: AL or CU, 100% Rated
Incoming lug types: AL mechanical lug
Device lock options
- Transformer:
3-phase
Type: DOE 2016 EX
Primary voltage: 480V
Secondary voltage: 208Y/120V
Rating: 15kVA, 30kVA, 45kVA, 75kVA and 12.5KVA
Winding material: AL and CU
Temperature rise: 80C, 115C and 150C
Primary or secondary transformer disconnects
- General:
-
Ratings & Options
- Available Enclosures:
NEMA Type 1, Type 1A (gaskets), Type 12, Type 3R
- Bussing Options:
Voltage Rating: 208 – 600V; 3-phase; 3 or 4 wire
Horizontal Bus Rating: 600 to 2500 A
Vertical Bus Rating: 300 to 600 A
Bus Withstand Rating 42kA to 100kA
- Monitoring, Surge Protective Devices & Incoming Connections:
Power Monitoring
Surge Protection: 120kA/phase to 240kA/phase
Incoming Connections: UL Service Entry Label, Cable or existing MCC section or Left or Right | Top or Bottom
Optional Seismic or Closed Door Racking
- Mains and Feeders:
Circuit breakers: electric trip and communications
Feeder circuit breakers: closed door racking, thermomagnetic or electric trip, and communications
Fusible switches
Main lug only
- Starters:
Full voltage and reduced voltage auto-transformer starters
Reversing, 2-speed options
Smart starter options: TeSys U or TeSys T
High density 6” starters
Circuit breaker or fusible switch disconnects
Extra mounting height
- AC Drives and Soft Starters:
Altivar 630 and 930
18 Pulse Drive
ATS22: IEC Contactors
ATS48: IEC or NEMA Contactors
- Automation:
Ethernet Com’X 510 Energy Server
- Available Enclosures: