How do you import CFG multi-loader files into SoMove software?
Issue:
How do you import CFG multi-loader files into SoMove Software?
Product Line:
VW3A8121
Environment:
All
Cause:
Needs to import a CFG file
Resolution:
Step 1: Using the Multi-loader Device you will need to save the CFG file into the Multi-loader by choosing Device to ML. This will save the file as a example 000001cfg on the SC memory card.
Step 2: Open SoMove Software Program on your laptop computer.
Step 3: Using the SoMove software you will need to create a new project by choosing drives part number and product firmware.
Step 4: In SoMove software find File Icon and choose Multi-loader and then Import file.
Step 5: Browse C drive to find your saved CFG file.
Step 6: After importing the CFG file into SoMove now you can save the project as PSX file by doing a Save.
Step 7: Now the CFG file has been imported into SoMove and You have Saved the new project as a PSX which is the SoMove file format.
Step 8: Complete.