Hôm nay chúng tôi có thể giúp gì cho bạn?

How to program an ATV61/71 drive to show speed as percentage instead of frequency?

Issue:
Programming an ATV61/71 drive to show speed as percentage instead of frequency.

Product Line:
ATV61, ATV71

Environment:
All models and serial numbers

Cause:
None

Resolution:

Show Output Frequency As a Percentage
  1. go to menu 2 , Access level = advanced or expert
  2. go to menu 7 , Display config menu
  3. go to menu 7.1, User parameters menu
  4. go to "Parameter selection"; choose Menu 1.2 [Monitoring].
  5. Select “Output Frequency”
  6. Esc until come back to the 7.1 User parameters menu
  7. Go to the "Customized selection "
  8. Select “Output Frequency”
  9. If you want to change the name from “Output Frequency to Output Percentage
    1. Choose “User Name”
    2. Turn the thumb wheel to scroll to the letter “O” then press the F3 button to move the cursor to the rightmost position, repeat selecting the next letter.  (note: to move back press F2 and to end and save this custom name press enter)
  10. Select “Unit” and select “%”
  11. Select “Multiplier” and enter “10”
  12. Select “Divisor” and select “6”
  13. Press Esc back to the MAIN MENU
  14. Press enter on the DRIVE MENU.
  15. Scroll to the MONITORING menu and press enter
  16. Scroll to the customized “User Name” you entered above.
  17. You should see the output frequency shown as a percentage.

Schneider Electric Việt Nam

Tìm hiểu thêm

Tìm hiểu thêm

Bạn cần trợ giúp?

Công cụ chọn sản phẩm

Nhanh chóng và dễ dàng tìm được sản phẩm và phụ kiện phù hợp cho các ứng dụng của bạn.

Nhận báo giá

Bắt đầu gửi yêu cầu bán hàng trực tuyến và chuyên gia sẽ liên hệ với bạn.

Nơi mua hàng?

Dễ dàng tìm nhà phân phối Schneider Electric gần bạn nhất.

Trung tâm Hỗ trợ

Tìm sự hỗ trợ cho mọi nhu cầu của bạn tại một nơi.