1.Issue:
Why some table columns disappear in EcoStruxure Machine SCADA Expert?
2. Product Line:
EcoStruxure Machine SCADA Expert
Harmony P6
Harmony iPC
Box iPC
Harmony GTU Open Box
3. Resolution:
Sometimes when we drag a column to the left and save the project, the column will disappear completely. The column is just not retracted it completely disappears and we cannot drag them to the right to increase the width. To solve the previous issue, we need to do the following:
With the program closed -> Follow the next path: C:\Users\USER\AppData\Local\EcoStruxure Machine Scada Expert 2020/ProgramSettings.ini. -> Open the file "programsettings.ini" with a text editor -> Locate the section with the problem "[Conf.sched.sch]" -> Then in the following lines under this section, we look for the desired column width and we modify it -> We save the file and check the change on EMSE.
If your file has extra lines of code compared to mine from the images, just ignore them. In case the column name does not appear, let's say you can't find the coumn "Disable=", please try typing it in the text file and then save.
If the above does not solve the problem, a reinstallation of EcoStruxure Machine SCADA Expert will be the next thing to try.
If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.
If you are not located in North America, please contact your local Customer Care Center for assistance:
Support | Schneider Electric Global (se.com)
Đã phát hành cho: Schneider Electric Việt Nam








Bạn cần trợ giúp?
Công cụ chọn sản phẩm
Nhanh chóng và dễ dàng tìm được sản phẩm và phụ kiện phù hợp cho các ứng dụng của bạn.
Nhận báo giá
Bắt đầu gửi yêu cầu bán hàng trực tuyến và chuyên gia sẽ liên hệ với bạn.
Nơi mua hàng?
Dễ dàng tìm nhà phân phối Schneider Electric gần bạn nhất.
Trung tâm Hỗ trợ
Tìm sự hỗ trợ cho mọi nhu cầu của bạn tại một nơi.