Workaround to access Data Quality Reports when encountering out-of-memory errors

Issue Description:

After running analysis, attempting to access the report tab within the Data Quality (DQ) tab results in the page failing to load. Subsequently, the browser throws an out-of-memory exception error.

Product Line:

Power Advisor

Cause:

The root cause of the issue is the large size of certain sites, which includes thousands of devices. This leads to a memory crash in the browser when attempting to load one month of data.

Resolution:

Workaround to Generate the Data Quality (DQ) Report

If you encounter issues generating the DQ report due to a memory crash, follow these steps:

  1. Generate a DQ Report from a Smaller Site:

2. Retrieve the Analysis Result ID from the Problematic Site:

  • On the problematic site, open Chrome Developer Tools (F12).
  • Run the analysis and navigate to the DQ tab.
  • In the Network tab, search for 'analysisResultId' and record the value.
    AnalysisResultID

3. Access the DQ Report: