Could not open connection to the host, on port 23 Error when trying to telnet to an ION meter.
Issue
Unable to make the telnet connection to an ION meter, the following message is returned:
Connecting To (ip address) XX.XXX.XXX.XXX....Could not open connection to the host, on port 23: Connect Failed.
Product Line
ION meters
Environment
Telnet connection to ION meters.
Cause
Windows Firewall may be blocking the Telnet inbound connection.
Resolutions
Test Telnet functionality again with an ION meter to ensure proper connectivity.
Unable to make the telnet connection to an ION meter, the following message is returned:
Connecting To (ip address) XX.XXX.XXX.XXX....Could not open connection to the host, on port 23: Connect Failed.
Product Line
ION meters
Environment
Telnet connection to ION meters.
Cause
Windows Firewall may be blocking the Telnet inbound connection.
Resolutions
- Click the Start menu then search for and open Windows Firewall.
- Select Advanced Settings.
- Select Inbound Rules from the left hand pane
- Under Inbound Rule Actions. select New Rule.
- For the Rule Type select Port, click next, then select TCP and Specific Local Ports.
- Enter 23 for the port number and click next.
- Select Allow Connection then click next.
- Specify when the new rule can be applied. (Domain, Private, and Public)
- Give the Inbound Rule a name such as "Telnet" then click finished.
Test Telnet functionality again with an ION meter to ensure proper connectivity.
Publikováno pro: Schneider Electric Česká republika
Zjistěte více
Řada:
Zjistěte více
Řada:
Potřebujete pomoc?
Nástroj pro výběr produktů
Rychle a snadno vyhledávejte správné produkty a příslušenství pro vaše aplikace.
Získejte nabídku
Poptejte se nás online a náš lokální specialista se s vámi spojí!
Kde nakoupit?
Jednoduše najděte nejbližšího distributora výrobků Schneider Electric ve vašem okolí.
Centrum nápovědy
Zdroje podpory pro všechny své potřeby najdete na jednom místě.