How to control the transparency of an object with a bool in EcoStruxure Operator Terminal Expert

Article available in these languages:

Issue:
Looking for an example on how to control the transparency of an object with a BOOL.

Product Line:
EcoStruxure Operator Terminal Expert

Resolution:
In order to control the transparency of an object with a BOOL, you must make use of a Converter that takes the value of the BOOL to output an Integer value that represents the percentage of Transparency.

1) To begin create a converter under the Convertor section in EcoStruxure Operator Terminal Expert.
EOTE converter2) Next, create a BOOL variable to use with the converter
3) In the object you wish to control the transparency, attach the BOOL variable at the Transparency property. While adding the BOOL, be sure to enable the Converter
EOTE Variable SelectorWhen the BOOL is False, the object will appear normal. When the BOOL is true, the object will be 50% transparent. NOTE: You can set your own value of transparency in the converter.

If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance:

Support | Schneider Electric Global (se.com)

Schneider Electric Česká republika

Zjistěte více

Potřebujete pomoc?

Nástroj pro výběr produktů

Rychle a snadno vyhledávejte správné produkty a příslušenství pro vaše aplikace.

Získejte nabídku

Poptejte se nás online a náš lokální specialista se s vámi spojí!

Kde nakoupit?

Jednoduše najděte nejbližšího distributora výrobků Schneider Electric ve vašem okolí.

Centrum nápovědy

Zdroje podpory pro všechny své potřeby najdete na jednom místě.