Uniflair Free Cooling Chillers

Free cooling chillers with axial fans and integrated free-cooling system for continuous operation applications

Del av Uniflair

The all-in-one integrated chilled water solution for data center cooling.

Uniflair Free Cooling Chillers
  • Funksjoner

    Free-cooling air cooled chillers leverages external air to remove the heat. These chillers not only reduce energy consumption compared to traditional systems, and therefore contribute to reduce global warming. Aquaflair FC unit are featured with embedded free-cooling, without increasing product footprint or clearances. All of Schneider Electric's Aquaflair Chillers offer low noise impact through the use of large air side heat exchangers, controlling fan rotation and insulated compressor section of the chiller. Our advanced controls system constantly monitors set points to guarantee the unit always operates within operating limits and will signal any faults before breakdown occurs. These chillers support a wide range of applications and maximize the availability of Row and Room cooling products to provide a complete heat removal solution

    Fordeler

    availabilityQuick restart - Full load operation in less than 3 minutes with specific arrangements permits undersizing of the storage tanksSeparate power input - Draws power from the external UPS for mainboards and heaters to monitor and protect the unit even in complete power failure mode (optional)Redundant Components - Single points of failure in the system have redundant components to maintain availability and reliability.Integrated free-cooling - Allows continuous operation in winter mode even with compressor failureContinuous current monitoring - Permits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).Electronic expansion valve - Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoringActive response control - Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.manageabilityBuilding management system integration - Send alarms and data points allowing you to manage critical building infrastructure from a single system.Local area network - Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situationsMicroprocessor controller - Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.Network interface - Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.serviceabilityEasy service access - Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.Operational Service - Allows critical components to be maintained/replaced while the system is in operation.Service monitoring - All the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.total cost of ownershipModular strategy - Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expediture and provides deferred investment throughout the life of the facility.Tandem compressors - Quiet and efficient operation of compressors, connected on a common refrigerant circuit for staged capacity control (not available for some models/configuration)Integrated Hydronics Package - Includes all the necessary components to make one connection to the chilller without the need of external connections to auxiliary equipment such as pumps, increasing the speed of deployment.Optimized management - Connection between the Computer Room Air Conditioners and the chillers guarantees energy efficiency, based on real instantaneous load conditions (optional)Variable speed fans - Variable speed fans reduce energy consumption during off-peak cooling periods.Integrated pumps adjustment system - (Optional) VSD onboard pumps are available for continuous adjustment of the chilled water loop available pressure. This provides automatic adjustments in Chilled water flow due to changes in cooling demand which ensures efficiency of the chilled water system.

Lurer du på noe?

Er det noe du lurer på, leter etter, eller noe du har lyst til å si til oss? Vår chat er åpen hver arbeidsdag mellom 7:30 og 16:00.

Slik bruker du produktkatalogen

Den 20.12.2017 forsvant vår gamle e-katalog for godt. Derfor har vi laget en enkel video som viser deg hvordan du bruker vår nye produktkatalog.

Trenger du support?

På våre tekniske support-sider finner du nyttige verktøy og dokumenter for alle produktene våre.

Finn erstatning for utgåtte produkter

Vi har fått et nytt verktøy som lar deg søke etter erstatninger til utfasede og utgåtte produkter, enkelt og oversiktlig.

Digitale produktkataloger - iPaper

Med iPaper får du enkel tilgang til produktinformasjon. Du kan blant annet søke på ord/el-nummer og lage egne brosjyrer med kun de sidene du trenger.

EcoStruxure™

Et enkelt, åpent IoT-system som sikrer pålitelighet og sikker drift, i tillegg til maksimal energieffektivitet.