How can I upload a project from an HMI using Vijeo Designer programming software?

Issue:
Uploading a project from an HMI using Vijeo Designer programming software.


Product Line:
Vijeo Designer, HMIGTO, HMISTU, HMIGTU, HMISTO5, XBTGT


Resolution:
1) Launch Vijeo Designer.
2) Right-click on Vijeo Manager and select "Upload Editor Project".
Upload

3) Select the method by which you wish to upload the project. You can upload via Ethernet, Serial, or USB. If you wish to upload via Ethernet, enter the IP address of the HMI.
Upload

If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.