What type of XPS safety relays should be used with XCSDM coded magnetic safety switches?

Article available in these languages: Dutch

XPSBAT, XPSUAB, XPSUAF, XPSUAK, XPSUAT, XPSUDN and XPSUS from our current XPSU range may be used for safety applications including Coded Magnetic Switches.

XPSMCM programmable safety relays may also be used.

NOTE that the XPSDM range are part of Telemecanique business, which were sold in 2023. You can contact Telemecanique through their website: www.telemecaniquesensors.com

You can find XPSU and XPSMCM catalogues on our digital web based catalogues, here: digicat.se.com. Click on 'General Catalogue' then 'PLC, PAC and other controllers', and finally 'Safety Controllers and Modules', you will then see the catalogues available.

General Information:

Coded Magnetic Switches (CMS) are used to monitor guards and gates and are components in safety related control systems.
They must be installed in accordance with standard EN 1088/ISO 14119 relating to guard locking and interlocking devices.

Which Coded Magnetic Switches to use:

For compliance with this standard, dynamic monitoring of a pair of opposed contacts (1 N/C + 1 N/O) must be practiced. Only XCSDM*5*** products have this contact setup and may be used.


Additional information:

XCSDM*7*** CMSs are not recommended for use in safety applications, since they do not comply with the current standard. These products have been developed to satisfy the obsolete machine market, before standard EN 1088 came into existence.

From our old XPS range of safety relays, only XPSDM may be used for this type of device

Caution: For Coded Magnetic Switches with 3 contacts, the 3rd contact (GY- PK) is a signalling contact which must never be wired onto the safety module.

Schneider Electric UK

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and contact centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings