inductance - detuned reactor - 6.5 kvar 400..415V 50 Hz - tuning order 4.3

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Varplus
    device short name
    DR
    product or component type
    Detuned reactor
    network frequency
    50 Hz
    reactive power rating
    6.5 kvar at 400...415 V AC 50 Hz
    network rated voltage
    400...415 V AC 50 Hz
    tuning order
    4.3 - 215 Hz - 5.7 % - 50 Hz
    Complementary
    power losses
    100 W
    value of inductance
    4.71 mH
    inductance tolerance
    - 5 % to 5 % per phase
    fundamental current rating
    9 A
    electrical insulation class
    Class H
    [Ui] rated insulation voltage
    1.1 kV
    dielectric test voltage
    4 kV for 1 minute at 50 Hz
    [Imp] maximum permanent current
    1.31 x I1
    harmonic current spectrum
    19 % x I7
    2 % x I3
    6 % x I11
    69 % x I5
    dynamic withstand current
    2.2 x Isc
    [Ith] conventional free air thermal current
    2 A at 250 V AC 50 Hz
    type of installation
    Indoor installation
    type of cooling
    Natural
    connections - terminals
    Screw type connector
    fixing center
    110 x 87 mm
    height
    230 mm
    width
    200 mm
    depth
    140 mm
    product weight
    8.6 kg
    Environment
    standards
    EN 60289
    IEC 60289
    IP degree of protection
    IP00
    operating altitude
    <= 2000 m
    ambient air temperature for operation
    0...55 °C at <= 1000 m
    0...50 °C at > 1000...2000 m
    average ambient air temperature for operation
    50 °C at <= 1000 m (average over 24 hours)
    40 °C at <= 1000 m (average over 1 year)
    45 °C at > 1000...2000 m (average over 24 hours)
    35 °C at > 1000...2000 m (average over 1 year)
    climatic withstand
    Relative humidity: 20...80 %
    Salt mist (400 V/50 Hz) : 250 hours
    Contractual warranty
    Warranty period
    12 months
  • Documents & Downloads

    Language
    • English
    User guide
    Date
    Size
    Add to My Documents
    User manual Detuned reactor (English)
Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.