Welcome to the Schneider Electric corporate Website

Select your location

View all   Marine
Schneider Electric G55TUPM20HMS Image

G55TUPM20HMS

Schneider Electric G55TUPM20HMS Image
G55TUPM20HMS

MGE Galaxy 5500 20kVA 400-415V Integrated Parallel UPS Marine IP22 RAL 7035, Start-up 5X8

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Overview
    Description
    UPS is designed to meet the marine standard requirement.
    Model Name
    MGE Galaxy 5500 20kVA 400-415V Integrated Parallel UPS Marine IP22 RAL 7035, Start-up 5X8
    Includes
    Installation guide , User Manual
    Standard Lead Time
    Special Order - Call for Quoted Lead Times
    Product Distribution
    Albania , Algeria , Angola , Anguilla , Antigua And Barbuda , Argentina , Armenia , Aruba , Austria , Azerbaijan , Bahamas , Bahrain , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bolivia , Bosnia And Herzegovina , Botswana , Brazil , Bulgaria , Burkina Faso , Burundi , Cameroon , Canada , Cayman Islands , Chile , China , Colombia , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Costa Rica , Cote D'Ivoire , Croatia , Cyprus , Czech Republic , Denmark , Djibouti , Dominica , Dominican Republic , Ecuador , Egypt , El Salvador , Eritrea , Estonia , Ethiopia , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Greece , Grenada , Guadeloupe , Guatemala , Guyana , French Guiana , Haiti , Honduras , Hong Kong , Hungary , Iceland , Iraq , Ireland , Israel , Italy , Jamaica , Jordan , Kazakhstan , Kenya , Kuwait , Latvia , Lebanon , Liberia , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Mexico , Mongolia , Morocco , Mozambique , Namibia , Netherlands , Netherlands Antilles , Nicaragua , Nigeria , Norway , Oman , Pakistan , Panama , Paraguay , Peru , Poland , Portugal , Puerto Rico , Qatar , Reunion , Romania , Russian Federation , Rwanda , SAINT KITTS AND NEVIS , SAINT LUCIA , SAINT VINCENT AND THE GRENADINES , Saudi Arabia , Senegal , Sierra Leone , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Suriname , Sweden , Switzerland , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Togo , Trinidad And Tobago , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , United States , Uruguay , Uzbekistan , Venezuela , VIRGIN ISLANDS (UNITED STATES) , Yemen , Zambia , Zimbabwe
    General
    Bypass Connection
    4 wire (3Ph + N) or 5 wire (3Ph + N + G)
    Bypass Voltage Tolerance
    +/-10% settable from +/-4/6/8 and 10%
    Max Bypass Input Current
    29 A
    Bypass Protection Device
    100 A
    Output
    Output Power Capacity
    18.0 KW / 20.0 kVA
    Max Configurable Power (Watts)
    18.0 KW / 20.0 kVA
    Nominal Output Voltage
    400 3PH
    Output Voltage Note
    Configurable for 400 or 415V 3 Phase nominal output voltage
    Output Voltage Distortion
    Less than 2%
    Output Frequency (sync to mains)
    50 Hz - programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8%
    Other Output Voltages
    380, 415V
    Crest Factor
    3 : 1
    Double Conversion Online
    Waveform Type
    Sine wave
    Output Voltage Tolerance
    +/- 2% static and 100% load step
    Output Voltage THD
    < 1% linear load and < 2.5% nonlinear load
    Overload Operation
    10 minutes @ 125% and 60 seconds @ 150%
    Required Output Current Protection
    29 A
    Neutral Output Current
    43 A
    Bypass
    Built-in Maintenance Bypass , Built-in Static Bypass , Optional External Bypass
    Input
    Nominal Input Voltage
    400 3PH
    Input Frequency
    45 - 65 Hz
    Input Connections
    Hard Wire 4-wire (3PH + G)
    Input voltage range for main operations
    323 - 437 (380V) V , 340 - 460 (400V) V , 353 - 477 (415V) V
    Other Input Voltages
    380 , 415
    Maximum Input Current
    42 A
    Input Breaker Capacity
    125 A
    Maximum Short Circuit Withstand (Icw)
    20.0
    Input Total Harmonic Distortion
    Less than 5% for full load
    Type of Input Protection Required
    gL fuse
    Batteries & Runtime
    Battery Type
    No internal battery - uses external battery system
    Communications & Management
    Available SmartSlot™ Interface Quantity
    3
    Pre-Installed SmartSlot™ Cards
    AP9635CH
    Control panel
    Multi-function LCD status and control console
    Emergency Power Off (EPO)
    Yes
    Physical
    Maximum Height
    2210.0 mm
    Maximum Width
    712.0 mm
    Maximum Depth
    855.0 mm
    Net Weight
    488.0 kg
    Shipping Weight
    510.0 kg
    Shipping Height
    2340.0 mm
    Shipping Width
    1080.0 mm
    Shipping Depth
    1200.0 mm
    Master Carton Units
    1.0
    Color
    Light grey
    Units per Pallet
    1.0
    Environmental
    Operating Environment
    0 - 40 °C
    Operating Relative Humidity
    0 - 95 %
    Operating Elevation
    0-999.9 meters
    Storage Temperature
    -20 - 45 °C
    Storage Relative Humidity
    0 - 95 %
    Storage Elevation
    0-3600 meters
    Audible noise at 1 meter from surface of unit
    65.000 dB
    Protection Class
    IP 20 , IP 32
    Conformance
    Approvals
    CE , EN/IEC 62040-1 , EN/IEC 62040-2 , EN/IEC 62040-3 , IEC 62040-2 , ISO 9001 , TUV , VDE
    Standard warranty
    1 year (parts only) , 1 year on-site repair or replace with factory authorized Start-Up
  • View more View less

    Documents

    Language
    • All Languages30
    • English11
    • Chinese2
    • Danish1
    • Dutch2
    • Finnish1
    • French2
    • German2
    • Italian2
    • Polish1
    • Russian2
    • Spanish2
    • Swedish1
    • Turkish1
    User guide
    Format
    Size
    Date
    Add to My Documents
    Galaxy 5500 20 - 120 kVA 400 V Installation (Version V3)
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy 5500 UPS
    prp.document.label.format pdf
    Size 7.1 MB
    Date 6/17/18
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy 5500 UPS
    Galaxy 5500 Marine / Off Shore Receiving and Unpacking (Version V2)
    Description
    Providing information on storage conditions and how to unpack the Galaxy 5500 Marine/Off shore cabinets, remove them from the pallet and mount specific parts
    prp.document.label.format pdf
    Size 3.5 MB
    Date 6/29/16
    Description
    Providing information on storage conditions and how to unpack the Galaxy 5500 Marine/Off shore cabinets, remove them from the pallet and mount specific parts
    MGE Galaxy 5500 20-120 kVA 400 V Safety and Handling (Version V0)
    Description
    Providing information on handling safety, operating environment, electrical safety, battery safety, battery storage time and regulatory agency approval
    prp.document.label.format pdf
    Size 433.9 KB
    Date 12/8/14
    Description
    Providing information on handling safety, operating environment, electrical safety, battery safety, battery storage time and regulatory agency approval
    Schneider Electric Important Safety Instructions (Version V0)
    Description
    Schneider Electric Important Safety Instructions in English, Chinese Simplified, French, German, European Spanish, Italian, Russian, Portuguese Brazilian, Dutch, Japanese and Korean
    prp.document.label.format pdf
    Size 1.1 MB
    Date 6/6/14
    Description
    Schneider Electric Important Safety Instructions in English, Chinese Simplified, French, German, European Spanish, Italian, Russian, Portuguese Brazilian, Dutch, Japanese and Korean
    Modbus Register Map for TCP IP- MGE Galaxy 5500 (Version V0)
    Files in document
    pdf
    38.6 KB
    pdf
    38.6 KB
    Description
    Documents the register values for the Modbus TCP IP implementation on the MGE Galaxy 5500
    prp.document.label.format zip
    Size 77.2 KB
    Date 5/29/14
    Files in document
    pdf
    38.6 KB
    pdf
    38.6 KB
    Description
    Documents the register values for the Modbus TCP IP implementation on the MGE Galaxy 5500
    prp.document.label.format pdf
    Size 7.2 MB
    Date 6/17/18
    prp.document.label.format pdf
    Size 474.1 KB
    Date 12/8/14
    prp.document.label.format pdf
    Size 519.9 KB
    Date 12/8/14
    prp.document.label.format pdf
    Size 7.1 MB
    Date 6/17/18
    prp.document.label.format pdf
    Size 523.2 KB
    Date 12/8/14
    prp.document.label.format pdf
    Size 513.5 KB
    Date 12/8/14
    prp.document.label.format pdf
    Size 6.9 MB
    Date 6/17/18
    prp.document.label.format pdf
    Size 521.6 KB
    Date 12/8/14
    prp.document.label.format pdf
    Size 7.1 MB
    Date 6/17/18
    prp.document.label.format pdf
    Size 527.5 KB
    Date 12/8/14
    prp.document.label.format pdf
    Size 7.1 MB
    Date 6/17/18
    prp.document.label.format pdf
    Size 518.1 KB
    Date 12/8/14
    prp.document.label.format pdf
    Size 524.9 KB
    Date 12/8/14
    prp.document.label.format pdf
    Size 7.2 MB
    Date 6/17/18
    prp.document.label.format pdf
    Size 529 KB
    Date 12/8/14
    prp.document.label.format pdf
    Size 7.2 MB
    Date 6/17/18
    prp.document.label.format pdf
    Size 519.9 KB
    Date 12/8/14
    prp.document.label.format pdf
    Size 518.9 KB
    Date 12/8/14
    prp.document.label.format pdf
    Size 520.9 KB
    Date 12/8/14
    CAD
    Format
    Size
    Date
    Add to My Documents
    G55TUP20K120HMS - MGE Galaxy 5500 20-120kVA 400-415V UPS Marine IP22 (Version V2)
    Files in document
    pdf
    1.1 MB
    zip
    23.9 MB
    Description
    MGE Galaxy 5500 Offshore & Marine,Mechanical
    prp.document.label.format zip
    Size 25 MB
    Date 1/16/18
    Files in document
    pdf
    1.1 MB
    zip
    23.9 MB
    Description
    MGE Galaxy 5500 Offshore & Marine,Mechanical
    G55TUPM20K60HBOTR2-SD - MGE Galaxy 5500 Offshore & Marine 20-60kVA UPS 1+1 MOD with Battey & Output XFMR System One Line (Version V0)
    Files in document
    pdf
    590.1 KB
    zip
    231.8 KB
    Description
    MGE Galaxy 5500 Offshore & Marine, System One Line
    prp.document.label.format zip
    Size 821.9 KB
    Date 7/22/14
    Files in document
    pdf
    590.1 KB
    zip
    231.8 KB
    Description
    MGE Galaxy 5500 Offshore & Marine, System One Line
    G55TUPM20K60HBR2-SD - MGE Galaxy 5500 Offshore & Marine 20-60kVA UPS 1+1 MOD with Battey Cabinet System One Line (Version V0)
    Files in document
    zip
    231.6 KB
    pdf
    571.1 KB
    Description
    MGE Galaxy 5500 Offshore & Marine, System One Line
    prp.document.label.format zip
    Size 802.8 KB
    Date 7/22/14
    Files in document
    zip
    231.6 KB
    pdf
    571.1 KB
    Description
    MGE Galaxy 5500 Offshore & Marine, System One Line
    G55TUPM20K120HR2-WD – MGE Galaxy 5500 Offshore & Marine 20-120kVA UPS 1+1 MOD Wiring Diagram (Version V0)
    Files in document
    zip
    157.7 KB
    pdf
    139.1 KB
    Description
    MGE Galaxy 5500 Offshore & Marine, System Wiring
    prp.document.label.format zip
    Size 296.9 KB
    Date 7/22/14
    Files in document
    zip
    157.7 KB
    pdf
    139.1 KB
    Description
    MGE Galaxy 5500 Offshore & Marine, System Wiring
    Certificate
    Format
    Size
    Date
    Add to My Documents
    DNV-GL TYPE APPROVAL CERTIFICATE FOR Galaxy 5500 Marine (Version V0)
    Description
    TYPE APPROVAL CERTIFICATE For Galaxy 5500 Marine
    prp.document.label.format pdf
    Size 77.3 KB
    Date 10/2/15
    Description
    TYPE APPROVAL CERTIFICATE For Galaxy 5500 Marine
    Specification for tender
    Format
    Size
    Date
    Add to My Documents
    Guide Specification- MGE Galaxy 5500 Marine (Version V0)
    Files in document
    pdf
    83.3 KB
    zip
    45.1 KB
    Description
    Guide specification for Galaxy 5500 Marine
    prp.document.label.format zip
    Size 128.4 KB
    Date 11/22/13
    Files in document
    pdf
    83.3 KB
    zip
    45.1 KB
    Description
    Guide specification for Galaxy 5500 Marine
  • Technical FAQs