RXG interface relays
Presentation and description
Presentation of the range

RXG relays are interface plug-in relays with Faston pins for better reliability and robust installation. They are used in PLC applications.

The RXG interface relay range comprises:

1 10 A relays with 1 CO contact and 5 A relays with 2 CO contacts
2 Sockets with separate or mixed contact terminals, built-in plastic maintaining clamp
3 Protection modules (diode, diode + LED, RC circuit, or varistor + LED) for RXG separate sockets
4 Clip-in legends for RXG separate sockets

These relays are available in both pre-assembled (single reference) and customer assembled offers.

Relay description
1 Push button for testing the contacts (blue: DC, red: AC)
2 Mechanical “relay status” indicator
3 Removable lock-down door enabling forced maintaining of the contacts for test sequences or maintenance purposes
4 LED (depending on version) indicating the relay status
5 Removable legend for relay identification
6 5 or 8 Faston type pins
7 Standard cover-type relay with pushbutton, mechanical indicator, and LED options
8 Basic cover-type relay with LED option
Socket description

Sockets with separate contact terminals (1)

1 Connection by screw connector
1b Connection by push-in terminal
2 5 or 8 female contacts for the relay pins
3 Hole for panel mounting
4 Location for protection modules
5 Built-in plastic maintaining clamp for locking components
6 Locating slot for mounting on DIN rail
7 Test point
8 Push button to release wire
9 Location for bus jumpers

Sockets with mixed contact terminals (2)

1 Connection by screw clamp
2 5 or 8 female contacts for the relay pins
3 Hole for panel mounting
4 Built-in plastic maintaining clamp for locking components
5 Locating slot for mounting on DIN rail
(1) The inputs and outputs are separate from the relay supply.
(2) The outputs NC are mixed with the relay supply, with the outputs NO and inputs being located on the opposite side of the socket.
Back to Top
References

RXG22BDPV

RXG relays: Pre-assembled interface relays

Pre-assembled interface relays

Relays mounted on screw connector separate terminal sockets with integrated clamp and protection module (sold in lots of 30)

Control circuit

voltage

V

Pre-assembled unit reference

Components in pre-assembled unit reference

Weight

g/lb

1 CO - 10A

2 CO - 5A

Relay

Socket (with

RGZR215 clamp)

Protection module

(with LED)

Relays with lockable test button and LED

24 c

RXG12BDPV


RXG12BD

RGZE1S35M

RZM031RB

59/0.130

24 a

RXG12B7PV


RXG12B7

RGZE1S35M

RZM021RB

59/0.130

230 a

RXG12P7PV


RXG12P7

RGZE1S35M

RZM021FP

59/0.130

24 c


RXG22BDPV

RXG22BD

RGZE1S48M

RZM031RB

66/0.145

24 a


RXG22B7PV

RXG22B7

RGZE1S48M

RZM021RB

67/0.148

230 a


RXG22P7PV

RXG22P7

RGZE1S48M

RZM021FP

67/0.148

Relays with LED

24 c

RXG13BDPV


RXG13BD

RGZE1S35M

RZM031RB

58/0.129

230 a

RXG13P7PV


RXG13P7

RGZE1S35M

RZM021FP

59/0.130

24 c


RXG23BDPV

RXG23BD

RGZE1S48M

RZM031RB

66/0.145

230 a


RXG23P7PV

RXG23P7

RGZE1S48M

RZM021FP

67/0.148

Relays with lockable test button and without LED

24 c


RXG21BDPV

RXG21BD

RGZE1S48M

RZM031RB

67/0.148

24 a


RXG21B7PV

RXG21B7

RGZE1S48M

RZM021RB

67/0.148

230 a


RXG21P7PV

RXG21P7

RGZE1S48M

RZM021FP

67/0.148

RXG12P7PVP

RXG relays: Pre-assembled interface relays

Relays mounted on push-in separate terminal sockets with integrated clamp (sold in lots of 10)

Control circuit

voltage

V

Pre-assembled unit reference

Components in pre-assembled unit reference

Weight

g/lb

1 CO - 10A

2 CO - 5A

Relay

Socket (with RGZR215 clamp)

Relays with lockable test button and LED

24 c

RXG12BDPVP


RXG12BD

RGZE05P

59/0.130

24 a

RXG12B7PVP


RXG12B7

RGZE05P

59/0.130

230 a

RXG12P7PVP


RXG12P7

RGZE05P

59/0.130

24 c


RXG22BDPVP

RXG22BD

RGZE08P

62/0.137

24 a


RXG22B7PVP

RXG22B7

RGZE08P

62/0.137

230 a


RXG22P7PVP

RXG22P7

RGZE08P

62/0.137

Relays with LED

24 c

RXG13BDPVP


RXG13BD

RGZE05P

59/0.130

230 a

RXG13P7PVP


RXG13P7

RGZE05P

59/0.130

24 c


RXG23BDPVP

RXG23BD

RGZE08P

62/0.137

230 a


RXG23P7PVP

RXG23P7

RGZE08P

62/0.137

Relays with lockable test button and without LED

24 c


RXG21BDPVP

RXG21BD

RGZE08P

62/0.137

24 a


RXG21B7PVP

RXG21B7

RGZE08P

62/0.137

230 a


RXG21P7PVP

RXG21P7

RGZE08P

62/0.137


RXG11BD

RXG22B7

RXG13BD

RXG26BD

RXG18P7

RXG relays: Interface relays for customer assembly

Interface relays for customer assembly

Control circuit voltage

V

Sold in lots of

Number and type of contacts - Thermal current (Ith)

1 CO - 10 A

2 CO - 5 A

Weight
g/lb

Unit reference

Unit reference

Standard cover relays with lockable test button

6 c

10

RXG21RD

20/0.044

12 c

10

RXG21JD

20/0.044

24 c

10

RXG11BD

RXG21BD

20/0.044

24 a

10

RXG11B7

RXG21B7

20/0.044

48 a

10

RXG21E7

20/0.044

120 a

10

RXG11F7

RXG21F7

20/0.044

230 a

10

RXG11P7

RXG21P7

20/0.044

Standard cover relays with lockable test button and LED

6 c

10

RXG12RD

20/0.044

12 c

10

RXG12JD

RXG22JD

20/0.044

24 c

10

RXG12BD

RXG22BD

20/0.044

48 c

10

RXG12ED

RXG22ED

20/0.044

110 c

10

RXG12FD

RXG22FD

20/0.044

24 a

10

RXG12B7

RXG22B7

20/0.044

48 a

10

RXG12E7

RXG22E7

20/0.044

120 a

10

RXG12F7

RXG22F7

20/0.044

220 a

10

RXG22M7

20/0.044

230 a

10

RXG12P7

RXG22P7

20/0.044

Standard cover relays with LED

12 c

10

RXG13JD

20/0.044

24 c

10

RXG13BD

RXG23BD

20/0.044

24 a

10

RXG13B7

RXG23B7

20/0.044

48 a

10

RXG23E7

20/0.044

120 a

10

RXG13F7

RXG23F7

20/0.044

220 a

10

RXG23M7

20/0.044

230 a

10

RXG13P7

RXG23P7

20/0.044

Basic cover relays with LED

24 c

10

RXG16BD

RXG26BD

19/0.042

230 a

10

RXG16P7

RXG26P7

19/0.042

Basic cover relays without LED

24 c

10

RXG18BD

RXG28BD

19/0.042

230 a

10

RXG18P7

RXG28P7

19/0.042

RGZE1S48M

RGZE05P

RGZE05E

RXG relays: Sockets for interface relays

Sockets for interface relays

Sockets with separate contact terminals arrangement, screw connector connection, and built-in clamp

Description

Thermal current (Ith)

Relay type

Sold in lots of

Unit Reference

Weight

g/lb

1 CO socket with 1 pole

10 A

RXG1●●●

10

RGZE1S35M

34/0.075

2 CO socket with 2 poles

5 A

RXG2●●●

10

RGZE1S48M

42/0.093

Sockets with separate contact terminals arrangement, push-in terminals, and built-in clamp

1 CO socket with 1 pole

10 A

RXG1●●●

10

RGZE05P

39/0.086

2 CO socket with 2 poles

5 A

RXG2●●●

10

RGZE08P

42/0.093

Sockets with mixed contact terminals arrangement, screw clamp connection, and built-in clamp

1 CO socket with 1 pole

10 A

RXG1●●●

10

RGZE05E

24/0.053

2 CO socket with 2 poles

5 A

RXG2●●●

10

RGZE08E

26/0.057

RZM031RB

RXG relays: Protection modules

Protection modules

Description

For use with

Voltage V

Sold in lots of

Unit reference

Weight
g/lb

Diode

All separate sockets

6…230 c

10

RZM040W

3/0.007

RC circuit

All separate sockets

24…60 a

10

RZM041BN7

10/0.022

110…240 a

10

RZM041FU7

10/0.022

Diode + green LED

All separate sockets

6…24 c

10

RZM031RB

4/0.009

24…60 c

10

RZM031BN

4/0.009

110…230 c

10

RZM031FPD

4/0.009

Varistor + green LED

All separate sockets

6…24 a/c

10

RZM021RB

5/0.011

24…60 a/c

10

RZM021BN

5/0.011

110…230 a/c

10

RZM021FP

5/0.011

RSZL300

RGZS08

RGZR215

RSZS02

RXG relays: Accessories

Accessories

Description

For use with

Sold in lots of

Unit reference

Weight
g/lb

Plastic maintaining clamp

All separate sockets (RGZE1S●●M, RGZE●●P)

10

RGZR215

2/0.004

Legend

All separate sockets (RGZE1S●●M, RGZE●●P)

10

RSZL300

2/0.002

Clip-in legends

(sheet of 16 legends)

RXG●1●●, RXG●2●●, RXG●3●● relays

10

RGZL520

1/0.002

Bus jumper

(8-pole jumper)

For inputs (A1, A2) of RGZE screw sockets (RGZE1S35M, RGZE1S48M)

10

RGZS08

5/0.013

Bus jumper

(2-pole jumper)

For input (A2) of RGZE push-in sockets (RGZE05P, RGZE08P)

10

RSZS02

2/0.004

Back to Top
  • Legal information
  • Privacy policy
  • Change your cookie settings

© 2025 Schneider Electric

Legal information
  • Our Purpose
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Financial Results
  • Annual Reports
  • Share Price
  • Investor Events
  • Sustainability
  • Electricity 4.0
  • Next-generation Automation
  • AI and Technology
  • Reports
  • Foundation
  • Consulting
  • Global - FR
  • Legal Information
  • Privacy Policy
  • Cookie Notice
  • Change your cookie settings