{}

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric corporate Website

Search FAQs
Supported TwinCAT-NC homing modes of Lexium32-EtherCAT?

Goals and Symptoms

Supported TwinCAT-NC homing modes of Lexium32-EtherCAT?

Causes and Fixes

Lexium32-EtherCAT supports the NC-homing mode "PLC_CAM" and "Software-Sync". For "Software-Sync", the encoder sub mask has to be set to 0x0001FFFF .
Homing modes with "hardware-latch" are not supported.


Legacy KB System (APS) Data: RESL204154 V1.0, Originally authored by JoAr on 12/15/2010, Last Edited by JoAr on 12/15/2010
Related ranges: Lexium 32

Schneider Electric Global

Explore more
Range:
Articles that might be helpful Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range: