Issue:
ATV61 and ATV71 drives ttHA high torque attained and ttLA low torque attained values in reference to torque
Product Line:
Altivar ATV61 and ATV71 drives
Environment:
All
Cause:
Motor Torque in percent
Resolution:
The high torque attained and low torque attained are between -300 to +300 % of rated motor torque of the motor. The default value is 100%.
[High tq. att.] (ttHA): Motor torque greater than high threshold [High torque thd.] (ttH)
v [Low tq. att.] (ttLA): Motor torque less than low threshold [Low torque thd.] (ttL)