Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Modicon ABE7
Schneider Electric ABE7E16SRM20 Image

ABE7E16SRM20

Green premium brand logo
Schneider Electric ABE7E16SRM20 Image
ABE7E16SRM20
Green premium brand logo

connection sub-base ABE7 - for Twido extension - 16 relay outputs

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon ABE7
    product or component type
    Discrete output sub-base
    [Us] rated supply voltage
    24 V DC for controller side
    24 V DC for sensor/controller side
    number of channels
    16
    number of terminal per channel
    2
    connections - terminals
    Screw type terminals, 1 x 0.09...1 x 1.5 mm² (AWG 28...AWG 16) flexible with cable end
    Screw type terminals, 1 x 0.14...1 x 2.5 mm² (AWG 26...AWG 12) solid
    Screw type terminals, 1 x 0.14...1 x 2.5 mm² (AWG 26...AWG 14) flexible without cable end
    Screw type terminals, 2 x 0.09...2 x 0.75 mm² (AWG 28...AWG 20) flexible with cable end
    Screw type terminals, 2 x 0.2...2 x 2.5 mm² (AWG 28...AWG 16) solid
    connector destination
    Twido programmable controller
    Complementary
    supply voltage limits
    19…30 V DC conforming to IEC 61131-2 (controller side)
    19…30 V DC conforming to IEC 61131-2 (sensor/controller side)
    discrete output number
    16 relay output(s), 3000 mA
    discrete output voltage
    110...250 V AC relay output(s)
    24 V DC solid state output(s)
    5...30 V DC relay output(s)
    discrete output function
    1 NO
    product compatibility
    TWDDDO16TK
    TWDDDO32TK
    status LED
    1 LED for power ON
    polarity distribution
    1 common/4 channels for relay output
    short-circuit protection
    2 A internal fuse, 5 x 20 mm, fast blow (controller side)
    connector type
    HE-10
    pin number
    20
    fixing mode
    By clips, mounting on 35 mm symmetrical DIN rail conforming to IEC 60715
    By screws
    maximum supply current
    2 A
    current per channel
    0.009 A relay output(s)
    switched current
    3000 mA for relay output
    maximum current per output common
    5 A for relay output
    voltage drop on power supply fuse
    0.3 V
    voltage state 0 guaranteed
    2 V relay output(s) (sensor/controller side)
    voltage state 1 guaranteed
    16.8 V relay output(s)
    electrical durability
    500000 cycles, maximum switching current: 2000 mA AC-12 relay output(s) (preactuator side)
    500000 cycles, maximum switching current: 3000 mA DC-12 relay output(s) (preactuator side)
    500000 cycles, maximum switching current: 400 mA AC-15 relay output(s) (preactuator side)
    500000 cycles, maximum switching current: 500 mA DC-13 relay output(s) (preactuator side)
    minimum switching current
    100 mA relay output(s)
    response time
    <= 2.5 ms from state 1 to 0 relay output(s)
    <= 5 ms from state 0 to 1 relay output(s)
    [Uimp] rated impulse withstand voltage
    6 kV relay output(s)
    switching frequency
    20 Hz relay
    mechanical durability
    20000000 cycles at 20 °C
    [Ui] rated insulation voltage
    2000 V between terminals/mounting rails
    300 V between coil circuit/contact circuits conforming to IEC 60947-1
    overvoltage category
    II conforming to IEC 60664-1
    tightening torque
    0.6 N.m with flat Ø 3.5 mm screwdriver
    net weight
    0.43 kg
    Environment
    product certifications
    CSA
    UL
    IP degree of protection
    IP2x conforming to IEC 60529
    resistance to incandescent wire
    750 °C conforming to IEC 60695-2-11
    shock resistance
    15 gn for 11 ms conforming to IEC 60068-2-27
    vibration resistance
    2 gn (f= 10…150 Hz) conforming to IEC 60068-2-6
    resistance to electrostatic discharge
    4 kV (contact) level 3 conforming to IEC 61000-4-2
    8 kV (air) level 3 conforming to IEC 61000-4-2
    resistance to radiated fields
    10 V/m (80000000…2000000000 Hz) conforming to IEC 61000-4-3 level 3
    resistance to fast transients
    2 kV level 3 conforming to IEC 61000-4-4
    ambient air temperature for operation
    -5…60 °C conforming to IEC 61131-2
    ambient air temperature for storage
    -40…80 °C conforming to IEC 61131-2
    pollution degree
    2 conforming to IEC 60664-1
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages20
    • English11
    • French5
    • German4
    • Italian4
    • Spanish4
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    User guide
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 8.8 MB
    Date 3/1/05
    Description
    None
    Size pdf
    Size 6 MB
    Date 3/1/05
    Description
    None
    Size pdf
    Size 8.9 MB
    Date 2/28/05
    Size pdf
    Size 6.1 MB
    Date 2/28/05
    Size pdf
    Size 9 MB
    Date 2/28/05
    Size pdf
    Size 6.1 MB
    Date 2/28/05
    Size pdf
    Size 6.1 MB
    Date 2/28/05
    Size pdf
    Size 8.9 MB
    Date 2/28/05
    Size pdf
    Size 6.1 MB
    Date 3/1/05
    Size pdf
    Size 8.9 MB
    Date 2/28/05
    CAD
    Format
    Size
    Date
    Add to My Documents
    Size zip
    Size 3.5 MB
    Date 11/8/07
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 1.7 MB
    Date 1/25/17
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    connection sub-base ABE7 - for Twido extension - 16 relay outputs
    Description
    connection sub-base ABE7 - for Twido extension - 16 relay outputs
    Size pdf
    Size 195.3 KB
    Date 12/9/19
    Description
    connection sub-base ABE7 - for Twido extension - 16 relay outputs
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    connection sub-base ABE7 - for Twido extension - 16 relay outputs
    Description
    connection sub-base ABE7 - for Twido extension - 16 relay outputs
    Size pdf
    Size 195.3 KB
    Date 12/9/19
    Description
    connection sub-base ABE7 - for Twido extension - 16 relay outputs
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    connection sub-base ABE7 - for Twido extension - 16 relay outputs
    Description
    connection sub-base ABE7 - for Twido extension - 16 relay outputs
    Size pdf
    Size 195.3 KB
    Date 12/9/19
    Description
    connection sub-base ABE7 - for Twido extension - 16 relay outputs
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    (1)
    ABE7BV10 / BV20 / BV20TB


  • Mounting and Clearance

    Mounting



  • Connections and Schema

    HE10 16 Channels



    Wiring Diagram


    (1)
    Inductive load


  • Performance Curves

    Curves for Determining Cable Type and Length According to the Current


    L
    Cable length
    IT
    Total current per sub base (A)
    IA
    Average current per channel (mA)
    (1)
    Cables ABFT2••••• c.s.a. 0.08 mm2 (AWG 28)

    The curves are given for a voltage drop of 1 V in the cable. For n volts tolerance, multiply the length determined from the graph by n.


    Temperature Derating Curves
    Electromechanical Relay Outputs


    (1)
    100 % of channels used
    (2)
    50 % of channels used


    Electrical Durability (in Millions of Operating Cycles) Conforming to IEC 60947-5-1
    DC Loads

    DC12 curves


    DC12
    control of resistive loads and of solid state loads isolated by optocoupler, l/R ≤ 1 ms.

    DC13 curves


    DC13
    switching electromagnets, L/R ≤ 2 x (Ue x Ie) in ms, Ue: rated operational voltage, Ie: rated operational current (with a protective diode on the load, DC12 curves must be used with a coefficient of 0.9 applied to the number in millions of operating cycles)

    AC Loads

    AC12 curves


    AC12
    control of resistive loads and of solid state loads isolated by optocoupler, cos ϕ ≥ 0.9.

    AC14 curves


    AC14
    control of small electromagnetic loads ≤ 72 VA, make: cos ϕ = 0.3, break: cos ϕ = 0.3.

    AC15 curves


    AC15
    control of electromagnetic loads > 72 VA, make: cos ϕ = 0.7, break: cos ϕ = 0.4.


Compare products: /