View all
Altivar 212

ATV212HD11N4
ATV212HD11N4
variable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21
Show more characteristics-
Characteristics
Main range of product Altivar 212product or component type Variable speed drivedevice short name ATV212product destination Asynchronous motorsproduct specific application Pumps and fans in HVACassembly style With heat sinknetwork number of phases 3 phasesmotor power kW 11 kWmotor power hp 15 hp[Us] rated supply voltage 380...480 V - 15...10 %supply voltage limits 323…528 Vsupply frequency 50...60 Hz - 5...5 %network frequency 47.5...63 HzEMC filter Class C2 EMC filter integratedline current 16.8 A at 480 V21.1 A at 380 VComplementary apparent power 17.1 kVA at 380 Vprospective line Isc 22 kAcontinuous output current 22.5 A at 380 V22.5 A at 460 Vmaximum transient current 24.8 A for 60 sspeed drive output frequency 0.5…200 Hznominal switching frequency 12 kHzswitching frequency 6...16 kHz adjustable12...16 kHz with derating factorspeed range 1…10speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tntorque accuracy +/- 15 %transient overtorque 120 % of nominal motor torque +/- 10 % for 60 sasynchronous motor control profile Voltage/frequency ratio, 2 pointsVoltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)Flux vector control without sensor, standardVoltage/frequency ratio - Energy Saving, quadratic U/fVoltage/frequency ratio, 5 pointsregulation loop Adjustable PI regulatormotor slip compensation Not available in voltage/frequency ratio motor controlAdjustableAutomatic whatever the loadlocal signalling 1 LED (red)DC bus energized:output voltage <= power supply voltageisolation Electrical between power and controltype of cable Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPRWithout mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVCWith UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVCelectrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14L1/R, L2/S, L3/T: terminal 16 mm² / AWG 6tightening torque 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)2.5 N.m, 22 lb.in (L1/R, L2/S, L3/T)supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protectionInternal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protectionanalogue input number 2analogue input type VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bitsVIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bitsVIB configurable PTC probe: 0...6 probes, impedance: 1500 OhmVIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bitssampling duration 2 ms +/- 0.5 ms F discrete2 ms +/- 0.5 ms R discrete2 ms +/- 0.5 ms RES discrete3.5 ms +/- 0.5 ms VIA analog22 ms +/- 0.5 ms VIB analogresponse time FM 2 ms, tolerance +/- 0.5 ms for analog output(s)FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)accuracy +/- 0.6 % (VIA) for a temperature variation 60 °C+/- 0.6 % (VIB) for a temperature variation 60 °C+/- 1 % (FM) for a temperature variation 60 °Clinearity error VIA: +/- 0.15 % of maximum value for inputVIB: +/- 0.15 % of maximum value for inputFM: +/- 0.2 % for outputanalogue output number 1analogue output type FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bitsFM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bitsdiscrete output number 2discrete output type Configurable relay logic: (FLA, FLC) NO - 100000 cyclesConfigurable relay logic: (FLB, FLC) NC - 100000 cyclesConfigurable relay logic: (RY, RC) NO - 100000 cyclesminimum switching current 3 mA at 24 V DC for configurable relay logicmaximum switching current 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)discrete input type F programmable 24 V DC, with level 1 PLC, impedance: 4700 OhmR programmable 24 V DC, with level 1 PLC, impedance: 4700 OhmRES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohmdiscrete input logic Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1)Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)acceleration and deceleration ramps Automatic based on the loadLinear adjustable separately from 0.01 to 3200 sbraking to standstill By DC injectionprotection type Overheating protection: driveThermal power stage: driveShort-circuit between motor phases: driveInput phase breaks: driveOvercurrent between output phases and earth: driveOvervoltages on the DC bus: driveBreak on the control circuit: driveAgainst exceeding limit speed: driveLine supply overvoltage and undervoltage: driveLine supply undervoltage: driveAgainst input phase loss: driveThermal protection: motorMotor phase break: motorWith PTC probes: motordielectric strength 3535 V DC between earth and power terminals5092 V DC between control and power terminalsinsulation resistance >= 1 mOhm 500 V DC for 1 minutefrequency resolution Display unit: 0.1 HzAnalog input: 0.024/50 Hzcommunication port protocol METASYS N2APOGEE FLNLonWorksBACnetModbusconnector type 1 open style1 RJ45physical interface 2-wire RS 485transmission frame RTUtransmission rate 9600 bps or 19200 bpsdata format 8 bits, 1 stop, odd even or no configurable paritytype of polarization No impedancenumber of addresses 1…247communication service Read holding registers (03) 2 words maximumTime out setting from 0.1 to 100 sWrite single register (06)Monitoring inhibitableWrite multiple registers (16) 2 words maximumRead device identification (43)option card Communication card for LonWorksoperating position Vertical +/- 10 degreewidth 180 mmheight 232 mmdepth 170 mmnet weight 6.45 kgpower dissipation in W 430 Wair flow 147 m3/hfunctionality Midspecific application HVACIP degree of protection IP21Variable speed drive application selection Compressor for scroll Building - HVACFan Building - HVACPump Building - HVACMotor power range AC-3 7…11 kW at 380…440 V 3 phases7…11 kW at 480…500 V 3 phasesmotor starter type Variable speed driveEnvironment electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-41.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6Voltage dips and interruptions immunity test conforming to IEC 61000-4-11pollution degree 2 conforming to IEC 61800-5-1IP degree of protection IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529IP21 conforming to EN/IEC 61800-5-1IP21 conforming to EN/IEC 60529IP41 on upper part conforming to EN/IEC 61800-5-1IP41 on upper part conforming to EN/IEC 60529vibration resistance 1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-61 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27environmental characteristic Classes 3C1 conforming to IEC 60721-3-3Classes 3S2 conforming to IEC 60721-3-3noise level 51 dB conforming to 86/188/EECoperating altitude 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m<= 1000 m withoutrelative humidity 5…95 % without condensation conforming to IEC 60068-2-35…95 % without dripping water conforming to IEC 60068-2-3ambient air temperature for operation -10…40 °C (without)40…50 °C (with derating factor)ambient air temperature for storage -25…70 °Cstandards EN 61800-3 category C2EN 61800-3 environments 1 category C2IEC 61800-3 category C3EN 61800-3 environments 1 category C3IEC 61800-3 environments 2 category C3UL Type 1IEC 61800-3 environments 1 category C1IEC 61800-3 environments 1 category C3EN 61800-3 environments 2 category C3EN 61800-3 environments 2 category C2EN 61800-3IEC 61800-3 category C2EN 61800-3 environments 1 category C1EN 61800-5-1EN 55011 class A group 1IEC 61800-3 environments 2 category C2EN 61800-3 category C3IEC 61800-5-1EN 61800-3 environments 2 category C1IEC 61800-3IEC 61800-3 environments 1 category C2IEC 61800-3 environments 2 category C1product certifications C-TickNOM 117CSAULmarking CEOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages40
- English23
- Chinese6
- Finnish4
- French7
- German6
- Italian6
- Russian4
- Spanish6
CatalogueFormatSizeAdd to My DocumentsSize pdfSize 16.6 MBDate 2/2/17Teollisuuden Tähtituotteet (Version 1.1)DescriptionTeollisuuden tähtituotteet: Altivar 212 – Taajuusmuuttajat kiinteistösovelluksiin, Harmony XB5R – Langaton ja paristovapaa painike, Harmony XVU – Superkirkas valotornisarja, Zelio RXG – Välirele Fast-on liitännälläSize pdfSize 2.1 MBDate 11/11/15DescriptionTeollisuuden tähtituotteet: Altivar 212 – Taajuusmuuttajat kiinteistösovelluksiin, Harmony XB5R – Langaton ja paristovapaa painike, Harmony XVU – Superkirkas valotornisarja, Zelio RXG – Välirele Fast-on liitännälläSize pdfSize 16.6 MBDate 2/2/17User guideFormatSizeAdd to My Documents3) ATV212 Programming Manual (Version 03)DescriptionThis programming manual is for Altivar 212 variable speed drives for synchronous and asynchronous motors.Size pdfSize 3.5 MBDate 11/7/14DescriptionThis programming manual is for Altivar 212 variable speed drives for synchronous and asynchronous motors.1) ATV212 快速入门指南 (Version 03)DescriptionATV212 Quick start (Chinese)Size pdfSize 1.7 MBDate 10/31/16DescriptionATV212 Quick start (Chinese)2_ATV212 安装手册 (Version 03)DescriptionATV212 Installation manual (Chinese)Size pdfSize 6.7 MBDate 11/7/14DescriptionATV212 Installation manual (Chinese)3) ATV212 编程手册 (Version 03)DescriptionATV212 programming manual (Chinese)Size pdfSize 5.1 MBDate 11/2/14DescriptionATV212 programming manual (Chinese)CADFormatSizeAdd to My DocumentsCAD for ATV212HD11N4: variable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21 (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for ATV212HD11N4: variable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21 (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD file (on TraceParts) for ATV212HD11N4: variable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21 (Version 2.0)DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.CAD file (on TraceParts) for ATV212HD11N4: variable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21 (Version 2.0)DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.CertificateFormatSizeAdd to My DocumentsInstruction sheetFormatSizeAdd to My DocumentsChina RoHS declarationFormatSizeAdd to My Documentsvariable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21Descriptionvariable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21Size pdfSize 195.3 KBDate 12/16/19Descriptionvariable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21End of Life InformationFormatSizeAdd to My DocumentsSize pdfSize 360.8 KBDate 7/1/11EU RoHS DeclarationFormatSizeAdd to My Documentsvariable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21Descriptionvariable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21Size pdfSize 195.3 KBDate 12/16/19Descriptionvariable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21Product Environmental ProfileFormatSizeAdd to My DocumentsSize pdfSize 313.9 KBDate 2/1/11Size pdfSize 316.1 KBDate 2/1/11REACh DeclarationFormatSizeAdd to My Documentsvariable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21Descriptionvariable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21Size pdfSize 195.3 KBDate 12/16/19Descriptionvariable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21 -
View more
Software and Firmware
Language- All Languages1
- English1
- Chinese1
- French1
- German1
- Italian1
- Spanish1
DTM filesFormatSizeAdd to My DocumentsAltivar DTM Library V12.8: ATV12, ATV31/312, ATV32, ATV61, ATV71, ATV LIFT, ATV212 (Version 12.8)Files in documentDescriptionAltivar DTM Library V12.7.0 = ATV12 (V2.0.1.0) + ATV31/312 (V2.0.2.0) + ATV32 (V2.0.10.0) + ATV61 (V2.0.3.0) + ATV71 (V2.0.3.0) + ATV LIFT(V1.9.2.0) + ATV212 (V2.0.1.0)Size zipSize 422.7 MBDate 5/2/18Files in documentDescriptionAltivar DTM Library V12.7.0 = ATV12 (V2.0.1.0) + ATV31/312 (V2.0.2.0) + ATV32 (V2.0.10.0) + ATV61 (V2.0.3.0) + ATV71 (V2.0.3.0) + ATV LIFT(V1.9.2.0) + ATV212 (V2.0.1.0) -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.