View all
Villaya Solar Water Pumping System

ATV312H075M2412
ATV312H075M2412
variable speed drive ATV312 - 0.75kW - 1.8kVA - 60W - 200..240 V- 1-phase supply
Show more characteristics-
Characteristics
Main range of product Altivar 312 Solarproduct or component type Variable speed driveproduct destination Asynchronous motorsproduct specific application Pumping station with photovoltaic arraysassembly style With heat sinkdevice short name ATV312Complementary motor power kW 0.75 kWmotor power hp 1 hp[Us] rated supply voltage 200...240 V - 5...5 %supply voltage limits 170…264 Vsupply frequency 50...60 Hz - 5...5 %network frequency 47.5...63 Hznetwork number of phases Single phaseline current 7.5 A at 240 V8.9 A at 200 V, Isc = 1 kAEMC filter Integratedapparent power 1.8 kVAprospective line Isc 1 kAcontinuous output current 4.8 A at 4 kHzmaximum transient current 7.2 A for 60 spower dissipation in W 60 W at nominal loadspeed drive output frequency 0.5…500 Hznominal switching frequency 4 kHzswitching frequency 2...16 kHz adjustablespeed range 1…50transient overtorque 150…170 % of nominal motor torquebraking torque <= 150 % during 60 s with braking resistor100 % with braking resistor continuously150 % without braking resistorasynchronous motor control profile Factory set: energy saving moderegulation loop Frequency PI regulatormotor slip compensation AdjustableAutomatic whatever the loadSuppressableoutput voltage <= power supply voltageelectrical connection Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 2.5 mm² AWG 14L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 2.5 mm² AWG 14tightening torque Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6: 0.6 N.mL1, L2, L3, U, V, W, PA, PB, PA/+, PC/-: 0.8 N.minsulation Electrical between power and controlsupply Internal supply for logic inputs at 19...30 V, <100 A, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (2.2 to 10 kOhm) at 10...10.8 V, <10 A, protection type: overload and short-circuit protectionanalogue input number 3analogue input type AI1 configurable voltage 0...10 V, input voltage 30 V max, impedance: 30000 OhmAI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance: 30000 OhmAI3 configurable current 0...20 mA, impedance: 250 Ohmsampling duration AI1, AI2, AI3: 8 ms analogLI1...LI6: 4 ms discreteresponse time AOV, AOC 8 ms for analogR1A, R1B, R1C, R2A, R2B 8 ms for discretelinearity error +/- 0.2 % for outputanalogue output number 2analogue output type AOC configurable current: 0...20 mA, impedance: 800 Ohm, resolution: 8 bitsAOV configurable voltage: 0...10 V, impedance: 470 Ohm, resolution: 8 bitsdiscrete input logic Logic input not wired (LI1...LI4), < 13 V (state 1)Negative logic (source) (LI1...LI6), > 19 V (state 0)Positive logic (source) (LI1...LI6), < 5 V (state 0), > 11 V (state 1)discrete output number 2discrete output type Configurable relay logic: (R1A, R1B, R1C) 1 NO + 1 NC - 100000 cyclesConfigurable relay logic: (R2A, R2B) NC - 100000 cyclesminimum switching current R1-R2 10 mA at 5 V DCmaximum switching current 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1-R2)2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1-R2)5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (R1-R2)5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (R1-R2)discrete input number 6discrete input type (LI1...LI6) programmable at 24 V, 0…100 mA for PLC, impedance: 3500 Ohmacceleration and deceleration ramps S, U or customizedLinear adjustable separately from 0.1 to 999.9 sbraking to standstill By DC injectionprotection type Input phase breaks: driveLine supply overvoltage and undervoltage safety circuits: driveLine supply phase loss safety function, for three phases supply: driveMotor phase breaks: driveOvercurrent between output phases and earth (on power up only): driveOverheating protection: driveShort-circuit between motor phases: driveThermal protection: motordielectric strength 2040 V DC between earth and power terminals2880 V AC between control and power terminalsinsulation resistance >= 500 mOhm 500 V DC for 1 minutelocal signalling 1 LED (red)drive voltage: Four 7-segment display unitsCANopen bus status:time constant 5 ms for reference changefrequency resolution Analog input: 0.1...100 HzDisplay unit: 0.1 Hzcommunication port protocol CANopenModbusconnector type 1 RJ45 for Modbus/CANopenphysical interface RS485 multidrop serial linktransmission frame RTUtransmission rate 10, 20, 50, 125, 250, 500 kbps or 1 Mbps for CANopen4800, 9600 or 19200 bps for Modbusnumber of addresses 1…127 for CANopen1…247 for Modbusnumber of drive 127 for CANopen31 for Modbuselectromagnetic compatibility 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3standards IEC 61800-5-1marking CEheight 145 mmwidth 72 mmdepth 142 mmnet weight 1.5 kgoption card Communication card for CANopen daisy chainCommunication card for DeviceNetCommunication card for FipioCommunication card for Modbus TCPCommunication card for Profibus DPEnvironment IP degree of protection IP20 without cover platepollution degree 2protective treatment TCvibration resistance 1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-61.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27relative humidity 5…95 % without condensation conforming to IEC 60068-2-35…95 % without dripping water conforming to IEC 60068-2-3ambient air temperature for storage -25…70 °Cambient air temperature for operation -10…50 °C without (with protective cover on top of the drive)-10…60 °C with derating factor (without protective cover on top of the drive)operating altitude <= 1000 m without>= 1000 m with current derating 1 % per 100 moperating position Vertical +/- 10 degreeOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages5
- English4
- French1
- Russian1
User guideFormatSizeAdd to My DocumentsATV312 Solar - simplified manual (Version 02)DescriptionVariable speed drives for pumps with photovoltaic arraysSize pdfSize 6 MBDate 2/19/16DescriptionVariable speed drives for pumps with photovoltaic arraysCertificateFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My Documentsvariable speed drive ATV312 - 0.75kW - 1.8kVA - 60W - 200..240 V- 1-phase supplyDescriptionvariable speed drive ATV312 - 0.75kW - 1.8kVA - 60W - 200..240 V- 1-phase supplySize pdfSize 195.3 KBDate 12/8/19Descriptionvariable speed drive ATV312 - 0.75kW - 1.8kVA - 60W - 200..240 V- 1-phase supplyREACh DeclarationFormatSizeAdd to My Documentsvariable speed drive ATV312 - 0.75kW - 1.8kVA - 60W - 200..240 V- 1-phase supplyDescriptionvariable speed drive ATV312 - 0.75kW - 1.8kVA - 60W - 200..240 V- 1-phase supplySize pdfSize 195.3 KBDate 12/8/19Descriptionvariable speed drive ATV312 - 0.75kW - 1.8kVA - 60W - 200..240 V- 1-phase supplyChina RoHS declarationFormatSizeAdd to My Documentsvariable speed drive ATV312 - 0.75kW - 1.8kVA - 60W - 200..240 V- 1-phase supplyDescriptionvariable speed drive ATV312 - 0.75kW - 1.8kVA - 60W - 200..240 V- 1-phase supplySize pdfSize 195.3 KBDate 12/8/19Descriptionvariable speed drive ATV312 - 0.75kW - 1.8kVA - 60W - 200..240 V- 1-phase supply -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.