  • Main
    range of product
    Modicon X80
    product or component type
    Analog input module
    electrical connection
    28 ways 1 connector
    Isolation between channels
    Non isolated
    input level
    High level
    analogue input number
    8
    analogue input type
    Current +/- 20 mA
    Current 0...20 mA
    Current 4...20 mA
    Voltage +/- 10 V
    Voltage +/- 5 V
    Voltage 0...10 V
    Voltage 0...5 V
    Voltage 1...5 V
    Complementary
    analog/digital conversion
    16 bits
    analogue input resolution
    15 bits + sign
    input impedance
    10 MOhm
    permitted overload on inputs
    +/- 30 mA 0...20 mA
    +/- 30 mA 4...20 mA
    +/- 30 V +/- 10 V
    +/- 30 V +/- 5 V
    +/- 30 V 0...10 V
    +/- 30 V 0...5 V
    +/- 30 V 1...5 V
    +/- 30 mA +/- 20 mA
    internal conversion resistor
    250 Ohm
    precision of internal conversion resistor
    0.1 % - 15 ppm/°C
    type of filter
    First order digital filtering
    fast read cycle time
    1 ms + 1 ms x number of channels used
    nominal read cycle time
    9 ms for 8 channels
    measurement error
    <= 0.1 % of full scale +/- 10 V 0...60 °C
    <= 0.1 % of full scale +/- 5 V 0...60 °C
    <= 0.1 % of full scale 0...10 V 0...60 °C
    <= 0.1 % of full scale 0...5 V 0...60 °C
    <= 0.1 % of full scale 1...5 V 0...60 °C
    <= 0.3 % of full scale +/- 20 mA 0...60 °C
    <= 0.3 % of full scale 0...20 mA 0...60 °C
    <= 0.3 % of full scale 4...20 mA 0...60 °C
    0.15 % of full scale +/- 20 mA 25 °C
    0.15 % of full scale 0...20 mA 25 °C
    0.15 % of full scale 4...20 mA 25 °C
    0.075 % of full scale +/- 10 V 25 °C
    0.075 % of full scale 0...10 V 25 °C
    0.075 % of full scale 0...5 V 25 °C
    0.075 % of full scale 1...5 V 25 °C
    0.075 % of full scale +/- 5 V 25 °C
    temperature drift
    30 ppm/°C +/- 10 V
    30 ppm/°C +/- 5 V
    30 ppm/°C 0...10 V
    30 ppm/°C 0...5 V
    30 ppm/°C 1...5 V
    50 ppm/°C +/- 20 mA
    50 ppm/°C 0...20 mA
    50 ppm/°C 4...20 mA
    recalibration
    Factory calibrated
    common mode between channels
    >= 80 dB
    digital value format
    +/- 32767 in user scale
    +/- 10000 by default
    isolation voltage
    1400 V DC between channels and ground
    1400 V DC between channels and bus
    50 V DC between channels
    measurement resolution
    0.36 mV +/- 10 V
    0.36 mV 0...10 V
    0.36 mV 0...5 V
    0.36 mV 1...5 V
    0.36 mV +/- 5 V
    1.4 µA +/- 20 mA
    1.4 µA 0...20 mA
    1.4 µA 4...20 mA
    maximum conversion value
    +/- 11.4 V +/- 10 V
    +/- 11.4 V 0...10 V
    +/- 11.4 V 0...5 V
    +/- 11.4 V 1...5 V
    0...30 mA +/- 20 mA
    0...30 mA 0...20 mA
    0...30 mA 4...20 mA
    0...30 mA +/- 5 V
    protective treatment
    TC
    operating altitude
    0...2000 m
    2000...5000 m with derating factor
    status LED
    1 LED (green)RUN:
    1 LED per channel (green)channel diagnostic:
    1 LED (red)ERR:
    1 LED (red)I/O:
    net weight
    0.165 kg
    power consumption in W
    0.55 W 24 V DC typical
    1.01 W 24 V DC maximum
    0.32 W 3.3 V DC typical
    0.48 W 3.3 V DC maximum
    Environment
    vibration resistance
    3 gn
    shock resistance
    30 gn
    ambient air temperature for storage
    -40…85 °C
    ambient air temperature for operation
    0…60 °C
    relative humidity
    5…95 % at 55 °C without condensation
    IP degree of protection
    IP20
    directives
    2014/35/EU - low voltage directive
    2014/30/EU - electromagnetic compatibility
    2012/19/EU - WEEE directive
    product certifications
    CE
    UL
    EAC
    CSA
    Merchant Navy
    RCM
    standards
    EN 61131-2
    EN 61000-6-4
    EN 61000-6-2
    EN 61010-2-201
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    158 g
    Package 1 Height
    5.5 cm
    Package 1 width
    11 cm
    Package 1 Length
    12 cm
    Unit Type of Package 2
    S02
    Number of Units in Package 2
    15
    Package 2 Weight
    2.696 kg
    Package 2 Height
    15 cm
    Package 2 width
    30 cm
    Package 2 Length
    40 cm
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages65
    • English33
    • Chinese8
    • French20
    • German8
    • Italian8
    • Spanish8
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 12.7 MB
    Date 1/31/20
    prp.document.label.format pdf
    Size 14.3 MB
    Date 2/21/20
    User guide
    Format
    Size
    Date
    Add to My Documents
    Modicon M580 Distributed PAC - Composite Automation Type Online Help (Version 00)
    Description
    This manual describes the hardware and software implementation of Modicon X80 analog/digital input/output modules that are configured in a Modicon M580 Distributed PAC system, when configured with EcoStruxureTM Automation Expert.
    prp.document.label.format pdf
    Size 1.9 MB
    Date 4/1/20
    Description
    This manual describes the hardware and software implementation of Modicon X80 analog/digital input/output modules that are configured in a Modicon M580 Distributed PAC system, when configured with EcoStruxureTM Automation Expert.
    Modicon X80 - Racks and Power Supplies, Hardware Reference Manual (Version 04)
    Description
    This document provides detailed information about the Modicon X80 racks and power supplies used for M340 station, M580 system, and X80 drops.
    prp.document.label.format pdf
    Size 3 MB
    Date 10/1/19
    Description
    This document provides detailed information about the Modicon X80 racks and power supplies used for M340 station, M580 system, and X80 drops.
    Modicon M580, Hardware Reference Manual (Version 10)
    Description
    This document provides detailed information about the M580 programmable automation controller (PAC), power supplies, and racks. These topics are also discussed:- Install a local rack in the M580 system.- Configure the M580 CPU.- The CPU performs Ethernet I/O scanning of both RIO and DIO logic without affecting network determinism.
    prp.document.label.format pdf
    Size 12.3 MB
    Date 10/1/19
    Description
    This document provides detailed information about the M580 programmable automation controller (PAC), power supplies, and racks. These topics are also discussed:- Install a local rack in the M580 system.- Configure the M580 CPU.- The CPU performs Ethernet I/O scanning of both RIO and DIO logic without affecting network determinism.
    Modicon M580 Standalone System Planning Guide for Frequently Used Architectures (Version 10)
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer and connecting an M580 local rack and M580 RIO drops.This guide provides detailed information about planning frequently used M580 architectures, including the following:- Ethernet I/O networks (RIO and distributed equipment integrated on the same physical network)- topology rules and recommendations for choosing a network configuration- role of network option switch modules- system commissioning and maintenance- system performance and limitations- system diagnostics
    prp.document.label.format pdf
    Size 18.2 MB
    Date 10/1/19
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer and connecting an M580 local rack and M580 RIO drops.This guide provides detailed information about planning frequently used M580 architectures, including the following:- Ethernet I/O networks (RIO and distributed equipment integrated on the same physical network)- topology rules and recommendations for choosing a network configuration- role of network option switch modules- system commissioning and maintenance- system performance and limitations- system diagnostics
    Modicon X80 - Analog input/output modules, User manual (Version 17)
    Description
    This manual describes the hardware and software implementation of Modicon X80 analog modules.
    prp.document.label.format pdf
    Size 6.8 MB
    Date 10/1/19
    Description
    This manual describes the hardware and software implementation of Modicon X80 analog modules.
    Modicon M580 - RIO Modules, Installation and Configuration Guide (Version 10)
    Description
    This document describes the adapter modules that can be used in X80 RIO drops.This guide describes 3 adapter modules:- BMECRA31210- BMXCRA31210- BMXCRA31200
    prp.document.label.format pdf
    Size 1.7 MB
    Date 10/1/19
    Description
    This document describes the adapter modules that can be used in X80 RIO drops.This guide describes 3 adapter modules:- BMECRA31210- BMXCRA31210- BMXCRA31200
    Modicon M580, Safety Manual (Version 05)
    Description
    This Safety Manual describes the modules of the M580 safety system with special regard as to how they meet the Safety requirements of the IEC 61508 standard. It provides detailed information on how to install, run, and maintain the system correctly in order to protect human beings as well as to prevent damage to environment, equipment, and production.
    prp.document.label.format pdf
    Size 12 MB
    Date 9/1/19
    Description
    This Safety Manual describes the modules of the M580 safety system with special regard as to how they meet the Safety requirements of the IEC 61508 standard. It provides detailed information on how to install, run, and maintain the system correctly in order to protect human beings as well as to prevent damage to environment, equipment, and production.
    Modicon M580, Safety System Planning Guide (Version 05)
    Description
    This Safety System Planning Guide describes the modules of the M580 Safety system with special regard to how they meet the Safety requirements of the IEC 61508. It provides detailed information on how to install, run, and maintain the system correctly in order to help protect human beings as well as to help prevent damage to environment, equipment, and production.
    prp.document.label.format pdf
    Size 7.9 MB
    Date 9/1/19
    Description
    This Safety System Planning Guide describes the modules of the M580 Safety system with special regard to how they meet the Safety requirements of the IEC 61508. It provides detailed information on how to install, run, and maintain the system correctly in order to help protect human beings as well as to help prevent damage to environment, equipment, and production.
    prp.document.label.format pdf
    Size 3.3 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 2.6 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 16.4 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 9.1 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 7.2 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 7.1 MB
    Date 9/1/19
    prp.document.label.format pdf
    Size 16.2 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 7.2 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 3.3 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 1.1 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 10.4 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 6.6 MB
    Date 9/1/19
    prp.document.label.format pdf
    Size 16.8 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 10.1 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 2.7 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 7.5 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 3.3 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 6.5 MB
    Date 9/1/19
    prp.document.label.format pdf
    Size 3.3 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 2.6 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 10.4 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 7.7 MB
    Date 10/1/19