Welcome to the Schneider Electric corporate Website

Select your location

View all   EasyLogic PM1000 series
Schneider Electric METSEPM1200 Image
Discontinued

METSEPM1200

Green premium brand logo
Schneider Electric METSEPM1200 Image
Discontinued
METSEPM1200
Green premium brand logo

PM1200 power meter with energy and demand - with communication

Show more characteristics
METSEPM1200 has not been replaced. Please contact your customer care center for more information.
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    PowerLogic PM1000
    device short name
    PM1200
    product or component type
    Power meter
    Complementary
    power quality analysis
    Up to the 9th harmonic
    type of measurement
    Current
    Voltage
    Frequency
    Active and reactive power
    Active and reactive energy
    Power factor
    supply voltage
    44...277 V AC 50/60 Hz
    44...277 V DC
    network frequency
    50/60 Hz
    maximum power consumption in VA
    3 VA at 240 V AC
    display type
    LED
    display resolution
    3 lines with 4 digits
    sampling rate
    20 samples/cycle
    measurement current
    50…6000 mA
    input type
    Current 0...5 A (impedance <= 0.1 Ohm)
    Current 0...1 A (impedance <= 0.1 Ohm)
    measurement voltage
    80…480 V AC 50/60 Hz phase to phase
    0…999000 V AC 50/60 Hz with external VT
    measurement accuracy
    Power 1 %
    Current 1 %
    Voltage 1 %
    Energy 1 %
    Frequency 0.1 %
    Power factor 1 %
    Apparent power 1 %
    accuracy class
    Class 2 reactive energy conforming to IEC 62053-23
    Class 1 active energy conforming to IEC 62053-21
    communication port protocol
    Modbus 19.2 kbauds
    communication port support
    RS485
    Environment
    electromagnetic compatibility
    Immunity to impulse waves: , conforming to IEC 61000-4-12
    Electrostatic discharge immunity test: , conforming to IEC 61000-4-2
    Susceptibility to electromagnetic fields: , conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test: , conforming to IEC 61000-4-4
    Conducted RF disturbances: , conforming to IEC 61000-4-6
    1.2/50 µs shock waves immunity test: , conforming to IEC 61000-4-5
    Immunity to microbreaks and voltage drops: , conforming to IEC 61000-4-11
    Conducted and radiated emissions: , class A, conforming to CISPR 11
    mounting mode
    Flush-mounted
    mounting support
    Panel
    type of installation
    Indoor installation
    overvoltage category
    III
    IP degree of protection
    IP51 front face: conforming to IEC 60529
    IP40 back: conforming to IEC 60529
    relative humidity
    5…95 %
    ambient air temperature for operation
    -10…60 °C
    ambient air temperature for storage
    -25…70 °C
    operating altitude
    0...2000 m
    standards
    IEC 62053-21
    IEC 62052-11
    width
    96 mm
    depth
    80 mm embedded:
    height
    96 mm
    net weight
    0.4 kg
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    EU RoHS Directive
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages13
    • English12
    • French2
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 3 MB
    Date 7/4/19
    PLSED310020EN Vigilohm Catalog (Web) (Version 2.0)
    Description
    Vigilohm Catalog English Web Version
    prp.document.label.format pdf
    Size 9.8 MB
    Date 3/28/19
    Description
    Vigilohm Catalog English Web Version
    prp.document.label.format pdf
    Size 17.2 MB
    Date 12/12/18
    CAD
    Format
    Size
    Date
    Add to My Documents
    POWER METER PM (Version 1.0)
    Files in document
    stp
    734.7 KB
    zip
    202.9 KB
    prp.document.label.format zip
    Size 937.6 KB
    Date 9/12/13
    Files in document
    stp
    734.7 KB
    zip
    202.9 KB
    Brochure
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 920.2 KB
    Date 5/11/20
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    METSEPM1200 : PM1200 power meter with energy and demand - with communication
    Description
    PM1200 power meter with energy and demand - with communication
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/31/20
    Description
    PM1200 power meter with energy and demand - with communication
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    ECDPM1000-V3a (Version 1.0)
    Description
    Declaration of conformity for PM1000 range
    prp.document.label.format pdf
    Size 635.4 KB
    Date 5/6/16
    Description
    Declaration of conformity for PM1000 range
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 220 KB
    Date 12/12/14
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    METSEPM1200 : PM1200 power meter with energy and demand - with communication
    Description
    PM1200 power meter with energy and demand - with communication
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/31/20
    Description
    PM1200 power meter with energy and demand - with communication
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 264.7 KB
    Date 12/12/14
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    METSEPM1200 : PM1200 power meter with energy and demand - with communication
    Description
    PM1200 power meter with energy and demand - with communication
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/31/20
    Description
    PM1200 power meter with energy and demand - with communication
    Technical leaflet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 301.9 KB
    Date 9/11/19
    prp.document.label.format zip
    Size 1.9 MB
    Date 5/22/15
    Files in document
    pdf
    301.9 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.