Welcome to the Schneider Electric corporate Website

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   PowerLogic PM8000 series
Schneider Electric METSEPM8243 Image

METSEPM8243

Schneider Electric METSEPM8243 Image
METSEPM8243

PowerLogic PM8000 - PM8243 DIN rail mount meter - intermediate metering

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range
    PowerLogic
    product name
    PowerLogic PM8000
    device short name
    PM8243
    product or component type
    Power meter
    Complementary
    power quality analysis
    conforming to EN 50160: 2010 compliance report
    conforming to IEEE 519: 2014 compliance report
    conforming to IEC 61000-4-30: class S power quality measurement
    up to the 63rd harmonic
    harmonic distortion
    waveform capture
    voltage sag and swell detection
    programmablity (logic and math functions)
    conforming to IEC 62586 power quality monitoring
    device application
    WAGES metering
    Power monitoring
    type of measurement
    Current
    Voltage
    Frequency
    Active and reactive power total
    Apparent power total
    Power factor total
    Active and reactive power per phase, rms
    Apparent power per phase, rms
    Power factor per phase, rms
    supply voltage
    90...415 V AC 45...65 Hz +/- 10 %
    110...415 V DC +/- 10 %
    network frequency
    50 Hz
    60 Hz
    [In] rated current
    1 A
    10 A
    5 A
    poles description
    1P + N
    3P + N
    3P
    power consumption in VA
    18 VA at 415 V AC
    display type
    Without display
    sampling rate
    256 samples/cycle
    measurement current
    50…10000 mA
    analogue input type
    Voltage (impedance 5 MOhm)
    Current (impedance 0.3 MOhm)
    measurement voltage
    57…400 V AC 42...69 Hz between phase and neutral
    100…690 V AC 42...69 Hz between phases
    frequency measurement range
    42…69 Hz
    number of inputs
    3 digital 30 V AC
    3 digital 60 V DC
    measurement accuracy
    Current +/- 0.1 %
    Voltage +/- 0.1 %
    Active energy +/- 0.2 %
    accuracy class
    Class 0.2S active energy conforming to IEC 62053-22
    Class 0.2 active energy conforming to ANSI C12.20
    Class 0.2 active power conforming to IEC 61557-12
    Class 0.5S reactive energy conforming to IEC 62053-24
    Class 0.5 power factor conforming to IEC 61557-12
    Class 0.2 voltage conforming to IEC 61557-12
    Class 0.2 current conforming to IEC 61557-12
    number of outputs
    1 pulse
    information displayed
    Voltage
    Current
    Frequency
    Power
    Energy consumption
    Harmonic distortion
    communication port protocol
    Modbus RTU at 115 kbauds - 2-wire
    ION at 115 kbauds - 2-wire
    DNP3
    IEC 61850
    Modbus TCP/IP
    Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
    RSTP 801.1d 2004
    communication port support
    Ethernet
    Screw terminal block: RS485
    communication network type
    IPv6 (internet protocol)
    data recording
    Harmonics logs
    Sag and swell logs
    GPS synchronisation
    Time stamping
    Data logs
    Trending/forecasting
    Waveform logs
    Alarm logs
    Sequence of event recording
    Min/max of instantaneous values
    Event logs
    memory capacity
    512 MB
    web services
    Customizable home page
    File upload/download via FTP
    File upload/download via SFTP
    Web server
    Alarm notification by e-mail
    Viewing of captured waveform (FTP)
    Viewing of captured waveform (web)
    HTTPS server
    communication service
    SMTP e-mail notification
    DHCP
    RSTP support
    NTP time synchronization
    PTP time synchronization
    cybersecurity
    Password protection
    Port hardening
    Enable/disable communication ports
    Robust security logs
    Syslog protocol support
    mounting mode
    Clip-on
    mounting support
    DIN rail
    installation category
    III
    Safety Construction
    III, 400…690 V conforming to IEC 61010-1:ed. 3
    III, 400…690 V conforming to EN 61010-1:ed. 3
    III, 347…600 V conforming to UL 61010-1:ed. 3
    III, 347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
    standards
    IEC 61557-12
    IEC 62052-11
    IEC 62053-22
    IEC 62053-24
    IEEE 1588
    IEC 62586-2
    IEC 61326-1
    product certifications
    CE
    CULus
    N998
    China RoHS
    width
    90.5 mm
    depth
    90.8 mm
    height
    90.5 mm
    net weight
    528 g
    Environment
    electromagnetic compatibility
    Electrostatic discharge conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
    Surge immunity test conforming to IEC 61000-4-5
    Conducted RF disturbances conforming to IEC 61000-4-6
    Magnetic field at power frequency conforming to IEC 61000-4-8
    Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
    Immunity to impulse waves conforming to IEC 61000-4-12
    Conducted and radiated emissions conforming to EN 55022
    Conducted and radiated emissions conforming to EN 55011
    Conducted and radiated emissions conforming to FCC part 15
    Conducted and radiated emissions conforming to ICES-003
    Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579
    Surge withstand conforming to IEEE C37.90.1
    IP degree of protection
    IP30 conforming to IEC 60529
    relative humidity
    5…95 %
    ambient air temperature for operation
    -25…70 °C
    ambient air temperature for storage
    -40…85 °C
    operating altitude
    3000 m
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    0.854 kg
    Package 1 Height
    14 cm
    Package 1 width
    14 cm
    Package 1 Length
    18.5 cm
    Unit Type of Package 2
    BB1
    Number of Units in Package 2
    1
    Package 2 Weight
    854 g
    Package 2 Height
    13.5 cm
    Package 2 width
    13.5 cm
    Package 2 Length
    18.4 cm
    Unit Type of Package 3
    S03
    Number of Units in Package 3
    8
    Package 3 Weight
    7.487 kg
    Package 3 Height
    30 cm
    Package 3 width
    30 cm
    Package 3 Length
    40 cm
    Offer Sustainability
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • View more View less

    Documents

    Language
    • All Languages25
    • English25
    • Chinese3
    • French3
    • German3
    • Italian3
    • Portuguese3
    • Russian3
    • Spanish3
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    PowerLogic Catalog - 247 pages Web (NO PRINTED VERSION AVAILABLE) (Version 8.5)
    Description
    Note that no printed catalogs are available but all necessary source files, in 13 sections, are available for download from the Shopping Kiosk.
    prp.document.label.format pdf
    Size 12.3 MB
    Date 1/25/20
    Description
    Note that no printed catalogs are available but all necessary source files, in 13 sections, are available for download from the Shopping Kiosk.
    User guide
    Format
    Size
    Date
    Add to My Documents
    PM8000 series user manual (Version 06)
    Description
    The document explains the configuration and operation of the PM8000 series meters.
    prp.document.label.format pdf
    Size 5 MB
    Date 11/1/19
    Description
    The document explains the configuration and operation of the PM8000 series meters.
    Upgrade PM89RD96 display firmware to v4.0.15 (Version 03)
    Description
    This document describes the process to upgrade RD96 display firmware to the latest version for use with PowerLogic™ ION9000, PM8000 or ION7400 series meters.
    prp.document.label.format pdf
    Size 167.3 KB
    Date 11/1/19
    Description
    This document describes the process to upgrade RD96 display firmware to the latest version for use with PowerLogic™ ION9000, PM8000 or ION7400 series meters.
    What’s new for Power and Energy Monitoring Systems — November 2019 (Version 00)
    Description
    This update provides a summary of technological advances in the Power and Energy Monitoring System offers, and the technical documentation accompanying their release.
    prp.document.label.format pdf
    Size 95.2 KB
    Date 11/1/19
    Description
    This update provides a summary of technological advances in the Power and Energy Monitoring System offers, and the technical documentation accompanying their release.
    Upgrade meter firmware to v2.2.1 (Version 03)
    Description
    This document describes the process to upgrade PowerLogic™ ION9000, PM8000 or ION7400 series meters to the latest firmware version. It also contains information about upgrading analog I/O option module firmware.
    prp.document.label.format pdf
    Size 947.6 KB
    Date 11/1/19
    Description
    This document describes the process to upgrade PowerLogic™ ION9000, PM8000 or ION7400 series meters to the latest firmware version. It also contains information about upgrading analog I/O option module firmware.
    IEC 61000-4-30 compliance and ION meters (Version 13)
    Description
    This technical note outlines the compliance of applicable PowerLogic meters with the International Electrotechnical Commission’s IEC 61000-4-30 (or “4-30”) standard, and is intended for personnelwith knowledge of power quality and power quality standards.
    prp.document.label.format pdf
    Size 112.4 KB
    Date 9/1/19
    Description
    This technical note outlines the compliance of applicable PowerLogic meters with the International Electrotechnical Commission’s IEC 61000-4-30 (or “4-30”) standard, and is intended for personnelwith knowledge of power quality and power quality standards.
    What’s new in PM8000 series meter firmware v2.1.0 (Version 00)
    Description
    Whats New in PM8000 v2.1.0 firmware. The following new features are included: Enhanced firmware upgrades, PTP time synchronization, Secure webserver (HTTPS), other
    prp.document.label.format pdf
    Size 92.4 KB
    Date 2/1/19
    Description
    Whats New in PM8000 v2.1.0 firmware. The following new features are included: Enhanced firmware upgrades, PTP time synchronization, Secure webserver (HTTPS), other
    prp.document.label.format chm
    Size 18 MB
    Date 10/16/18
    What’s new in PM8000 series firmware v1.4.1 - EN (Version 00)
    Description
    Firmware version v1.4.1 for the PM8000 series meter adds security enhancements, new communications functionality, increased onboard log storage capacity, a webpage waveform viewer and other improvements.
    prp.document.label.format pdf
    Size 97.7 KB
    Date 12/5/17
    Description
    Firmware version v1.4.1 for the PM8000 series meter adds security enhancements, new communications functionality, increased onboard log storage capacity, a webpage waveform viewer and other improvements.
    What’s new in PM8000 series firmware v1.3.1 - EN (Version 00)
    Description
    Firmware version v1.3.1 for the PM8000 series meter adds Internal clock temperature compensation feature and resolves previously unknown Modbus master issue. This document also contains IPv6 global addressing and IPv6 gateway support content from the previous what's new document (7EN12-0295).
    prp.document.label.format pdf
    Size 188 KB
    Date 7/1/16
    Description
    Firmware version v1.3.1 for the PM8000 series meter adds Internal clock temperature compensation feature and resolves previously unknown Modbus master issue. This document also contains IPv6 global addressing and IPv6 gateway support content from the previous what's new document (7EN12-0295).
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 725 KB
    Date 12/23/16
    prp.document.label.format pdf
    Size 218.5 KB
    Date 7/4/16
    prp.document.label.format pdf
    Size 237.1 KB
    Date 7/4/16
    prp.document.label.format pdf
    Size 648.7 KB
    Date 4/20/16
    prp.document.label.format pdf
    Size 1.6 MB
    Date 1/15/16
    prp.document.label.format pdf
    Size 968.5 KB
    Date 3/30/15
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    PowerLogic Analog I/O option module (Version 00)
    Description
    Installation instructions
    prp.document.label.format pdf
    Size 5.3 MB
    Date 3/1/19
    Description
    Installation instructions
    PowerLogic PM8243 (Version 03)
    Description
    The installation guide for PowerLogic PM8243 power and energy DIN-mount meter describes mounting, wiring, connecting and verifying operation of the meter.
    prp.document.label.format pdf
    Size 3.1 MB
    Date 2/8/18
    Description
    The installation guide for PowerLogic PM8243 power and energy DIN-mount meter describes mounting, wiring, connecting and verifying operation of the meter.
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    METSEPM8243 : METSEPM8243_ROHS_CHINA_DECLARATION
    Description
    METSEPM8243_ROHS_CHINA_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 7/5/20
    Description
    METSEPM8243_ROHS_CHINA_DECLARATION
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 121.6 KB
    Date 7/24/19
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    METSEPM8243 : PowerLogic PM8000 - PM8243 DIN rail mount meter - intermediate metering
    Description
    PowerLogic PM8000 - PM8243 DIN rail mount meter - intermediate metering
    prp.document.label.format pdf
    Size 195.3 KB
    Date 7/5/20
    Description
    PowerLogic PM8000 - PM8243 DIN rail mount meter - intermediate metering