Main range of product Easergy P3product or component type Protection relayrelay application Universalproduct reference P3U30-6AAA2BCAApower supply 48...230 V AC/DCmeasuring inputs : 1/5 A CT phase current 3 : 1/5 A CT residual current 1 : 100 V/110 V VT voltage 4number of sensors 0 temperature sensor(s) 0 arc sensor(s)number of Digital Inputs (DI) 16number of Digital Outputs (DO) 1 watchdog8number of analogue inputs 0number of analogue outputs 0communication ports USB port 1 frontRJ45 2 rearcommunication protocols IEC 61850 ed. 1IEC 61850 ed. 2IEC 60870-5-101DNP3 TCPModbus TCPEthernet/IPredundancy communication port protocol RSTPPRPcybersecurity Port hardeningPassword protectionprotection functions Phase overcurrent 50/51Directional phase overcurrent 67Earth fault overcurrent 50N/51NDirectional earth fault 67NTransient earth fault 67NICapacitor bank unbalance 51CBroken conductor 46 I2/I1Cold load pick-upSwitch ON to fault (SOTF)Breaker failure 50BFDirectional active underpower 37PFault locator 21FLRecloser 79Phase undercurrent 37Excessive starting time, locked rotor 48/51LRMotor restart inhibition 66Capacitor overvoltage 59CNegative sequence overcurrent 46Overvoltage 59Undervoltage 27Positive sequence undervoltage 27PEarth fault overvoltage 59NUnderfrequency 81/81NRate of change of frequency 81RSynchro-check 25Lockout relay 86CT supervision 60VT supervision 60H2 detection 68H2H5 detection 68H5Programmable stages 99H5 detectionProgrammable curvearc flash protection Nomeasurement functions Current 3-phaseCurrent zero sequenceCurrent positive sequenceCurrent negative sequenceCurrent ratio of negative and positiveVoltage phase to earthVoltage phase to phaseVoltage zero sequenceVoltage positive sequenceVoltage negative sequenceVoltage ratio of negative and positiveShort circuit fault reactanceFault location currentEarth fault reactanceFrequencyActive powerRMS active powerReactive powerRMS reactive powerApparent powerRMS apparent powerActive energyReactive energyCos φTan φPower anglePower factorVoltage phasor diagram viewCurrent phasor diagram viewCurrent 2nd, 15th harmonics with THDVoltage 2nd, 15th harmonics with THDVoltage interruptionCondition monitoring CB wearcontrol functions Switchgear control and monitoringProgrammable switchgear interlockingLocal control on single-line diagramLocal control with I/O keysLocal/remote control2 function keysMobile application with Easergy SmartAppWeb-serverProgrammable logiccontrollable switchgear devices 4 controlled + 8 displayednumber of setting groups 4monitoring functions Trip circuit supervision 74Circuit breaker monitoringRelay self-monitoringlogs and records Event recordingDisturbance recordingTripping contextswitchgear diagnosis type CT/VT supervision ANSI code: 60CT supervisionTrip circuit supervision ANSI code: TCSconnections - terminals Screw removable (digital input/output)Ring lugs removable (current transformer)Pin removable (voltage transformer)Complementary operating threshold 110...230 V AC/DCtime synchronisation protocol SNTPweb server Embedded HTTP serversoftware name EcoStruxure Power DeviceESetup Easergy Pronumber of key 2 customizablelocal signalling 4 LEDs8 LEDs programmablestandards IECheight 169.5 mmwidth 170 mmdepth 205 mmnet weight 2.5 kg maximumEnvironment electromagnetic compatibility Emission tests conforming to IEC/EN 60255-26 ed. 3Emission tests class A conforming to CISPR 11Emission tests class A conforming to CISPR 22EMC immunity conforming to IEC/EN 60255-26 ed. 3EMC immunity conforming to EN/IEC 61000-4-18EMC immunity level 4 conforming to EN/IEC 61000-4-2EMC immunity level 3 conforming to EN/IEC 61000-4-3EMC immunity level 4 conforming to EN/IEC 61000-4-4EMC immunity level 3 conforming to EN/IEC 61000-4-5EMC immunity level 3 conforming to EN/IEC 61000-4-6EMC immunity conforming to EN/IEC 61000-4-8EMC immunity level 5 conforming to EN/IEC 61000-4-9EMC immunity conforming to EN/IEC 61000-4-29EMC immunity conforming to EN/IEC 61000-4-11EMC immunity conforming to EN/IEC 61000-4-17mechanical robustness Vibrations (level: class II) conforming to IEC 60255-21-1Vibrations: Fc conforming to IEC 60068-2-6Shocks (level: class II) conforming to IEC 60255-21-2Shocks: Ea conforming to IEC 60068-2-27Seismic tests method A (level: class II) conforming to IEC 60255-21-3Bumps (level: class II) conforming to IEC 60255-21-2Bumps: Ea conforming to IEC 60068-2-27climatic withstand Exposure to dry heat Bb tests conforming to EN/IEC 60068-2-2Exposure to cold Ad tests conforming to EN/IEC 60068-2-1Exposure to damp heat in service Db tests conforming to EN/IEC 60068-2-30Exposure to damp heat in service Cab tests conforming to EN/IEC 60068-2-78ambient air temperature for operation -40…65 °Cambient air temperature for storage -40…70 °CIP degree of protection IP54 conforming to IEC 60529relative humidity 0…95 %, without condensationmaximum operating altitude 2000 mprotective treatment Conformal coatingOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty Up to 10 years extended warranty (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions) -
View more
Documents
Language- English18
CatalogueFormatSizeAdd to My DocumentsEasergy P3 Catalog (Version 16)DescriptionNetwork protection relaySize pdfSize 6.3 MBDate 7/16/19DescriptionNetwork protection relayCADFormatSizeAdd to My DocumentsEasergy P3 connection diagrams (Version 1.0)Files in documentSize zipSize 24.7 MBDate 12/20/18Files in documentInstruction sheetFormatSizeAdd to My DocumentsGlobal Quick Guide for Easergy P3 (Version 3)Files in documentSize zipSize 5.8 MBDate 5/22/18Files in documentEnd of Life InformationFormatSizeAdd to My DocumentsProduct End of Life Instructions - Easergy P3U (Version 1.0)DescriptionThis document explains the dismantling of the medium voltage protection relays of the Easergy P3 Standard range.Size pdfSize 269.3 KBDate 10/1/17DescriptionThis document explains the dismantling of the medium voltage protection relays of the Easergy P3 Standard range.EU RoHS DeclarationFormatSizeAdd to My DocumentsEasergy P3U 3CT 1Io 4VT 16DI 8DO 48-230V DI24V 2LCDescriptionEasergy P3U 3CT 1Io 4VT 16DI 8DO 48-230V DI24V 2LCSize pdfSize 195.3 KBDate 12/14/19DescriptionEasergy P3U 3CT 1Io 4VT 16DI 8DO 48-230V DI24V 2LCMoviesFormatSizeAdd to My DocumentsProduct Environmental ProfileFormatSizeAdd to My DocumentsProduct Environmental Profile Easergy P3U30 (Version 1.0)DescriptionThe document describe the Product Environnemental Profile for Easergy P3U30.Size pdfSize 364.7 KBDate 10/1/17DescriptionThe document describe the Product Environnemental Profile for Easergy P3U30.REACh DeclarationFormatSizeAdd to My DocumentsEasergy P3U 3CT 1Io 4VT 16DI 8DO 48-230V DI24V 2LCDescriptionEasergy P3U 3CT 1Io 4VT 16DI 8DO 48-230V DI24V 2LCSize pdfSize 195.3 KBDate 12/14/19DescriptionEasergy P3U 3CT 1Io 4VT 16DI 8DO 48-230V DI24V 2LCChina RoHS declarationFormatSizeAdd to My DocumentsEasergy P3U 3CT 1Io 4VT 16DI 8DO 48-230V DI24V 2LCDescriptionEasergy P3U 3CT 1Io 4VT 16DI 8DO 48-230V DI24V 2LCSize pdfSize 195.3 KBDate 12/14/19DescriptionEasergy P3U 3CT 1Io 4VT 16DI 8DO 48-230V DI24V 2LC -
View more
Software and Firmware
Language- English2
Software - ReleasedFormatSizeAdd to My DocumentseSetup Easergy Pro V2.1.0 (Version 2.1.0)DescriptionThe eSetup Easergy Pro software is the setting and operating tool for Easergy protection relays. It may be used:|- prior to commissioning and without connection to Easergy relays, to prepare Easergy protection and parameter settings, during commissioning, on a PC connected point-to-point to the Easergy relays front panel: to load, unload and modify protection and parameter settings and to obtain all measurements and useful information during commissioning|- during operation, on a PC connected to a set of Easergy relays via Ethernet communication network in order to manage the protection system, to monitor the status of the electrical network and to run diagnostics on any incidents affecting the electrical network.||Compatibility with Microsoft® VISTA, XP Windows 7 (32/64) and Windows 10||Compatibility with Easergy P3 devives and Easergy P5 devices.Size zipSize 147.9 MBDate 10/10/19DescriptionThe eSetup Easergy Pro software is the setting and operating tool for Easergy protection relays. It may be used:|- prior to commissioning and without connection to Easergy relays, to prepare Easergy protection and parameter settings, during commissioning, on a PC connected point-to-point to the Easergy relays front panel: to load, unload and modify protection and parameter settings and to obtain all measurements and useful information during commissioning|- during operation, on a PC connected to a set of Easergy relays via Ethernet communication network in order to manage the protection system, to monitor the status of the electrical network and to run diagnostics on any incidents affecting the electrical network.||Compatibility with Microsoft® VISTA, XP Windows 7 (32/64) and Windows 10||Compatibility with Easergy P3 devives and Easergy P5 devices.WAVEWIN Data Management and Analysis System software (Version 6)DescriptionThis software is intended for use by individuals working in protection, engineering, and system operations to show the Waveforms from the protection devices.Size zipSize 4.9 MBDate 3/1/17DescriptionThis software is intended for use by individuals working in protection, engineering, and system operations to show the Waveforms from the protection devices. -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Connections and Schema
Functional View -
Dimensions Drawings
Base Unit DimensionsA
B
With screw connector
214 mm/8.43”
192 mm/7.6”
With ring-lug connector
226 mm/8.90”