View all Zelio Control Relays
Schneider Electric RM35JA31MW Image

RM35JA31MW

Green premium brand logo
Schneider Electric RM35JA31MW Image
RM35JA31MW
Green premium brand logo

current control relay RM35-J - range 2..500 mA

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Control
    product or component type
    Modular measurement and control relays
    relay type
    Current control relay
    relay name
    RM35JA
    relay monitored parameters
    Overcurrent or undercurrent in window mode
    Overcurrent or undercurrent detection
    time delay
    Adjustable 1...20 s, 0 + 10 % on energisation Ti
    Adjustable 0.3...30 s, 0 + 10 % on crossing the threshold Tt
    switching capacity in VA
    1250 VA
    minimum switching current
    10 mA at 5 V DC
    maximum switching current
    5 A AC
    maximum power consumption in VA
    3.5 VA AC
    measurement range
    10...100 mA E2-M terminals
    2...20 mA E1-M terminals
    2...500 mA current
    50...500 mA E3-M terminals
    utilisation category
    AC-12 conforming to IEC 60947-5-1
    AC-13 conforming to IEC 60947-5-1
    AC-14 conforming to IEC 60947-5-1
    AC-15 conforming to IEC 60947-5-1
    DC-12 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    DC-14 conforming to IEC 60947-5-1
    Complementary
    reset time
    1500 ms time delay
    maximum switching voltage
    250 V AC
    [Us] rated supply voltage
    24...240 V AC/DC 50/60 Hz +/- 10 %
    supply voltage limits
    20.4…264 V AC/DC
    operating voltage tolerance
    - 15 % + 10 % Un
    maximum power consumption in W
    0.6 W DC
    control circuit frequency
    40...70 Hz +/- 10 %
    resistance across terminals
    1 Ohm at E2-M terminals
    5 Ohm at E1-M terminals
    0.2 Ohm at E3-M terminals
    output contacts
    2 C/O
    nominal output current
    5 A
    maximum measuring cycle
    30 ms measurement cycle as true rms value
    hysteresis
    5…50 % of threshold setting
    delay at power up
    0.3 s
    measurement accuracy
    +/- 10 % of the full scale value
    repeat accuracy
    +/- 0.5 % for input and measurement circuit
    +/- 2 % for time delay
    measurement error
    0.05 %/°C with temperature variation
    1 by volt over the whole range with voltage variation
    polarity
    No DC
    threshold setting
    10...100 %
    marking
    CE : EMC 89/336/EEC
    CE : 73/23/EEC
    overvoltage category
    III conforming to IEC 60664-1
    insulation resistance
    > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5
    > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1
    > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5
    > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1
    > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5
    > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1
    [Ui] rated insulation voltage
    250 V conforming to IEC 60664-1
    operating position
    Any position without
    connections - terminals
    Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
    Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
    Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
    tightening torque
    0.6…1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    local signalling
    LED (green)power ON:
    LED (yellow)relay ON:
    mounting support
    35 mm symmetrical DIN rail conforming to EN/IEC 60715
    electrical durability
    100000 cycles
    mechanical durability
    30000000 cycles
    operating rate
    <= 360 operations/hour full load
    safety reliability data
    MTTFd = 296.8 years
    B10d = 270000
    contacts material
    Cadmium free
    width
    35 mm
    net weight
    0.13 kg
    Environment
    immunity to microbreaks
    50 ms
    electromagnetic compatibility
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
    standards
    EN/IEC 60255-6
    product certifications
    GL
    CSA
    GOST
    UL
    C-Tick
    ambient air temperature for storage
    -40…70 °C
    ambient air temperature for operation
    -20…50 °C
    relative humidity
    95 % at 55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6
    1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1
    shock resistance
    15 gn for 11 ms conforming to IEC 60255-21-1
    IP degree of protection
    IP20 (terminals) conforming to IEC 60529
    IP30 (casing) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2 kV, 1 min AC 50 Hz conforming to IEC 60255-5
    2 kV, 1 min AC 50 Hz conforming to IEC 60664-1
    non-dissipating shock wave
    4 kV conforming to IEC 60255-5
    4 kV conforming to IEC 60664-1
    4 kV conforming to IEC 61000-4-5
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages18
    • English17
    • French5
    • German4
    • Italian4
    • Spanish4
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 8.1 MB
    Date 6/24/19
    Size pdf
    Size 7.1 MB
    Date 6/24/19
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD for RM35JA31MW: current control relay RM35-J - range 2..500 mA (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    CAD for RM35JA31MW: current control relay RM35-J - range 2..500 mA (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for RM35JA31MW: current control relay RM35-J - range 2..500 mA (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for RM35JA31MW: current control relay RM35-J - range 2..500 mA (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Zelio Control RM35 CCC Certificate 2011010303495614 (Version 1.0)
    Description
    RM35 CCC Certificate 2011010303495614
    Size pdf
    Size 3 MB
    Date 5/23/19
    Description
    RM35 CCC Certificate 2011010303495614
    UL Listed RM17, RM22, RM35, RM8487 (Version 1.0)
    Files in document
    pdf
    475.7 KB
    pdf
    473.4 KB
    Description
    NRNT_NRNT7_E173076_Control
    Size zip
    Size 949 KB
    Date 5/19/15
    Files in document
    pdf
    475.7 KB
    pdf
    473.4 KB
    Description
    NRNT_NRNT7_E173076_Control
    CSA Certificate RM17, RM22, RM35, RM8487 (Version 1.0)
    Description
    MC248382_Class 3211-07_Control
    Size htm
    Size 213 B
    Date 5/18/15
    Description
    MC248382_Class 3211-07_Control
    EAC Certificate RM4 RM17 RM22 RM35 (Version 1.0)
    Description
    EAC Certificate RU C-FR.AИ96.B.00632
    Size pdf
    Size 1 MB
    Date 3/17/15
    Description
    EAC Certificate RU C-FR.AИ96.B.00632
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 619.5 KB
    Date 4/1/19
    RM35 JA... Current control, 2...500 mA, 0,15...15 A (Version 02)
    Description
    Functions: Overcurrent or undercurrent
    Size pdf
    Size 403.6 KB
    Date 11/1/07
    Description
    Functions: Overcurrent or undercurrent
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 5.4 MB
    Date 5/1/19
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    current control relay RM35-J - range 2..500 mA
    Description
    current control relay RM35-J - range 2..500 mA
    Size pdf
    Size 195.3 KB
    Date 11/15/19
    Description
    current control relay RM35-J - range 2..500 mA
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 5.4 MB
    Date 5/1/19
    Size pdf
    Size 2.2 MB
    Date 11/1/11
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    current control relay RM35-J - range 2..500 mA
    Description
    current control relay RM35-J - range 2..500 mA
    Size pdf
    Size 195.3 KB
    Date 11/15/19
    Description
    current control relay RM35-J - range 2..500 mA
    RoHs China Declaration
    Format
    Size
    Date
    Add to My Documents
    current control relay RM35-J - range 2..500 mA
    Description
    current control relay RM35-J - range 2..500 mA
    Size pdf
    Size 195.3 KB
    Date 11/15/19
    Description
    current control relay RM35-J - range 2..500 mA
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Current Control Relays
    Dimensions and Mounting



  • Connections and Schema

    Current Control Relays
    Wiring Diagram



    Application Schemes
    Example: Detection of Jamming on a Crusher (Overcurrent Function)

    Current measured ≤ 15 A


    Current measured > 15 A



  • Technical Description

    Function Diagrams
    Undercurrent Detection

    Without memory ("No Memory" mode)


    With memory ("Memory" mode)


    Overcurrent Detection

    Without memory ("No Memory" mode)


    With memory ("Memory" mode)


    Legend

    Ti Starting inhibition time delay

    Tt Time delay after crossing of threshold

    Un Supply voltage

    I Monitored current

    H Hysteresis

    I> Overcurrent threshold

    I< Undercurrent threshold

    11-12/11-14, 21-22/21-24 Output relay connections

    Relay status: black color = energized.

    NOTE: In "Memory" mode, the relay opens when crossing of the threshold is detected and then stays in that position. The power supply voltage must be switched off to reset the product.


Compare products: /