G5K 80 KVA 480V UPS with Stand Alone Batt UL924 BACKUP 90 Min

Show more characteristics
The maximum number of products that can be compared is 4

  • Overview
    Description
    UPS and three UL 924 listed matching battery cubicles with a minimum of 90 minutes battery operation.
    Model Name
    G5K 80 KVA 480V UPS with Stand Alone Batt UL924 BACKUP 90 Min
    Includes
    Installation guide
    Standard Lead Time
    Usually Ships within 2 Weeks
    Product Distribution
    Canada , United States
    Output
    Output Power Capacity
    72.0 KW / 80.0 kVA
    Max Configurable Power (Watts)
    72.0 KW / 80.0 kVA
    Nominal Output Voltage
    480 3PH , 600 3PH
    Output Voltage Distortion
    Less than 2%
    Output Frequency (sync to mains)
    60 Hz
    Crest Factor
    3 : 1
    Double Conversion Online
    Waveform Type
    Sine wave
    Output Connections
    (1) Hard Wire 4-wire (3PH + G) (Battery Backup)
    Output Voltage Tolerance
    +/- 1% static and +/- 2 % at 100% load step
    Output Voltage THD
    < 1% linear load and < 2.5% nonlinear load
    Overload Operation
    10 minutes @ 125% and 30 seconds @ 150%
    Bypass
    Internal Bypass (Automatic and Manual) , Optional External Bypass
    Input
    Nominal Input Voltage
    480 3PH
    600 3PH
    Input Frequency
    45 - 65 Hz
    Input Connections
    Hard Wire 4-wire (3PH + G)
    Input voltage range for main operations
    408 - 552 (480) V
    Maximum Input Current
    154 A
    Input Breaker Capacity
    250 A
    Maximum Short Circuit Withstand (Icw)
    20.0
    Input Total Harmonic Distortion
    Less than 3% for full load
    Type of Input Protection Required
    3-pole breaker
    Batteries & Runtime
    Battery Type
    No internal battery - uses external battery system
    Communications & Management
    Available SmartSlot™ Interface Quantity
    3
    Control panel
    Multi-function LCD status and control console
    Emergency Power Off (EPO)
    Optional
    Physical
    Maximum Height
    1905.0 mm
    Maximum Width
    4415.0 mm
    Maximum Depth
    813.0 mm
    Net Weight
    6792.73 kg
    Shipping Weight
    6797.27 kg
    Shipping Height
    1930.0 mm
    Shipping Width
    4660.0 mm
    Shipping Depth
    838.0 mm
    Environmental
    Operating Environment
    0 - 40 °C
    Operating Relative Humidity
    0 - 95 %
    Operating Elevation
    0-999.9 meters
    Storage Temperature
    -20 - 45 °C
    Storage Relative Humidity
    0 - 95 %
    Storage Elevation
    0-12000 meters
    Audible noise at 1 meter from surface of unit
    63.000 dB
    Online Thermal Dissipation
    19791.000 BTU/hr
    Protection Class
    IP 20
    Conformance
    Approvals
    UL 1778 , UL 924 Listed
    Standard warranty
    1 year on-site repair or replace with factory authorized Start-Up
  • View more View less

    Documents

    Language
    • English8
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    MGE Galaxy 5000 for Emergency Lighting and Power Equipment (Version 3)
    Description
    Product brochure for UL 924
    prp.document.label.format pdf
    Size 708.9 KB
    Date 2/25/13
    Description
    Product brochure for UL 924
    User guide
    Format
    Size
    Date
    Add to My Documents
    Galaxy 5000 40-130 kVA 480 V Installation Manual (NAM) (Version 1)
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy 5000 UPS
    prp.document.label.format pdf
    Size 7.3 MB
    Date 8/13/17
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy 5000 UPS
    Galaxy 5000 40-130 kVA 480 V Receiving & Unpacking (Version 0)
    Description
    Providing information on storage conditions and how to unpack the Galaxy 5000 cabinets and remove them from the pallet
    prp.document.label.format pdf
    Size 3.4 MB
    Date 11/16/16
    Description
    Providing information on storage conditions and how to unpack the Galaxy 5000 cabinets and remove them from the pallet
    CAD
    Format
    Size
    Date
    Add to My Documents
    SUG580S90UL - G5K 80kVA UPS 480V Stand alone Battery Cabinet UL924 Backup 90min (Version 1)
    Files in document
    Description
    MGE Galaxy 5000, UL924, Package
    prp.document.label.format zip
    Size 8.1 MB
    Date 12/30/13
    Files in document
    Description
    MGE Galaxy 5000, UL924, Package
    Specification guide
    Format
    Size
    Date
    Add to My Documents
    MGE Galaxy 5000 40-130 kVA 480 V Technical Specifications (Version 0)
    Description
    Contains Technical Data, Facility Planning, Drawings, Options, Warranty
    prp.document.label.format pdf
    Size 965.2 KB
    Date 12/2/11
    Description
    Contains Technical Data, Facility Planning, Drawings, Options, Warranty
    Certificate
    Format
    Size
    Date
    Add to My Documents
    UL 924 approval for MGE Galaxy 5000 UPS (Version 2)
    Description
    Approval doc for UL 924 for MGE Galaxy 5000 UPS
    prp.document.label.format pdf
    Size 15.4 KB
    Date 5/25/12
    Description
    Approval doc for UL 924 for MGE Galaxy 5000 UPS
    Specification for tender
    Format
    Size
    Date
    Add to My Documents
    CSI 2004/1995 MGE Galaxy 5000 40-130 kVA 480 V (Version 2)
    Files in document
    pdf
    162.5 KB
    zip
    40.7 KB
    Description
    Guide Specification
    prp.document.label.format zip
    Size 203.2 KB
    Date 2/20/13
    Files in document
    pdf
    162.5 KB
    zip
    40.7 KB
    Description
    Guide Specification
    CSI 2004/1995 MGE Galaxy 5000 Parallel Module 40-130 kVA 480 V (Version 0)
    Files in document
    pdf
    127 KB
    zip
    39.6 KB
    Description
    Guide Specification
    prp.document.label.format zip
    Size 166.7 KB
    Date 12/15/09
    Files in document
    pdf
    127 KB
    zip
    39.6 KB
    Description
    Guide Specification
  • Technical FAQs