Show more characteristics-
Characteristics
Main range of product Preventa Safety automationproduct or component type Analogue input cardsafety module name XPS MF60safety use category Category 4 maximum conforming to EN 954-1Performance level e conforming to EN/ISO 13849-1SIL 3 conforming to EN/IEC 61508function of module 2-pole measuring of - 10 to 10 V voltagesClosed circuit scanning of input channelsSingle-pole measuring of - 10 V to 10 V voltagesSingle-pole measuring of 0 to 20 mA currentsstandards DIN V 0801IEC 61131DIN V 19250EN 50156 pending[Us] rated supply voltage 24 V DC - 15...20 %group of channels 1 group of 8 or 2 groups of 4 inputsanalogue input number 4 bipolar isolated8 unipolar isolatedconnections - terminals Removable screw terminal block, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) flexible without cable endRemovable screw terminal block, 1 x 0.14...2 x 1.5 mm² (AWG 28...AWG 16) solid without cable endRemovable screw terminal block, 1 x 0.25...1 x 0.5 mm² (AWG 22...AWG 20) flexible with cable endRemovable screw terminal block, 1 x 0.25...1 x 1.5 mm² (AWG 22...AWG 16) flexible without cable endRemovable screw terminal block, 2 x 0.14...2 x 0.5 mm² (AWG 28...AWG 20) solid without cable endRemovable screw terminal block, 2 x 0.14...2 x 0.75 mm² (AWG 28...AWG 18) flexible without cable endRemovable screw terminal block, 2 x 0.25...2 x 0.34 mm² (AWG 22) flexible without cable endRemovable screw terminal block, 2 x 0.5 mm² (AWG 20) flexible with cable endComplementary marking CEexternal resistance 250 Ohm500 Ohmanalogue input range 0...20 mA with shunt- 10...10 Vinput voltage limits +/- 10.7 V maximum+/- 10.25 Vinput current limits 0…20.5 mA with shuntinput overvoltage protection -15…15 Vinternal resistance 1 MOhmanalogue input resolution 12 bits maximum9 bits effectivesafety accuracy <= +/-1 % for analogue input circuittransient deviation <= +/-1 %acquisition period Once per CPU cycleprocessing time 45 µsnumber of terminal blocks 2current consumption 150 mA at 3.3 V DC rack380 mA at 24 V DC power supplynet weight 0.24 kgEnvironment product certifications CSAULTÜVC-TickIP degree of protection IP20 (with covering plate on unused in rack I/O card slots)ambient air temperature for operation 0…60 °C conforming to EN/IEC 61131-2ambient air temperature for storage -40…85 °C conforming to EN/IEC 61131-2relative humidity 95 % supply not connectedoperating altitude < 2000 mpollution degree 2electrical shock protection class Class II conforming to IEC 61131-2electromagnetic compatibility EN/IEC 61131-2vibration resistance 1 gn (f = 10…150 Hz) - 10 cycles per axis - conforming to EN 61131-2shock resistance 15 gn for 11 ms (2 cycles per axis) conforming to EN 61131-2resistance to electrostatic discharge 4 kV contact conforming to EN/IEC 61000-4-28 kV on air conforming to EN/IEC 61000-4-2resistance to electromagnetic fields 10 V/m (26…1000 MHz), amplitude modulation 80 % conforming to EN/IEC 61000-4-3Offer Sustainability REACh Regulation EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages13
- English5
- French4
- German1
- Italian1
- Portuguese1
- Spanish1
CatalogueFormatSizeAdd to My DocumentsUser guideFormatSizeAdd to My DocumentsXPSMFWIN Software Manual (Version 02)DescriptionThis manual is a quick and easy start for learning XPSMFWIN. It includes anoverview of all functions and step-by-step instructions on creating a project.Size pdfSize 8.2 MBDate 7/1/07DescriptionThis manual is a quick and easy start for learning XPSMFWIN. It includes anoverview of all functions and step-by-step instructions on creating a project.XPSMF60 / XPSMF40 Manuel de sécurité (Version 05)DescriptionCe manuel contient des informations pour une utilisation.correcte des équipements d’automatisme de sécurité XPSMF60/XPSMF40. La connaissance des réglementations et l’application correcte des informations de sécurité contenues dans ce manuel de la part de personnel qualifié sont des conditions préalables à l’installation, le démarrage, le fonctionnement et l’utilisation sécurisés des équipements d’automatisme XPSMF60/XPSMF40.Size pdfSize 762 KBDate 3/1/17DescriptionCe manuel contient des informations pour une utilisation.correcte des équipements d’automatisme de sécurité XPSMF60/XPSMF40. La connaissance des réglementations et l’application correcte des informations de sécurité contenues dans ce manuel de la part de personnel qualifié sont des conditions préalables à l’installation, le démarrage, le fonctionnement et l’utilisation sécurisés des équipements d’automatisme XPSMF60/XPSMF40.China RoHS declarationFormatSizeAdd to My DocumentsXPSMFAI801_ROHS_CHINA_DECLARATIONDescriptionXPSMFAI801_ROHS_CHINA_DECLARATIONSize pdfSize 195.3 KBDate 12/12/19DescriptionXPSMFAI801_ROHS_CHINA_DECLARATIONEU RoHS DeclarationFormatSizeAdd to My DocumentsXPSMFAI801_ROHS_DECLARATIONDescriptionXPSMFAI801_ROHS_DECLARATIONSize pdfSize 195.3 KBDate 12/12/19DescriptionXPSMFAI801_ROHS_DECLARATIONREACh DeclarationFormatSizeAdd to My DocumentsXPSMFAI801_REACH_DECLARATIONDescriptionXPSMFAI801_REACH_DECLARATIONSize pdfSize 195.3 KBDate 12/12/19DescriptionXPSMFAI801_REACH_DECLARATION -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.