View all
Preventa XU

XUSLBR5A1520
XUSLBR5A1520
safety light curtain type 4 - XUSLB - for hand protection - 1520 mm
Show more characteristics
Commercial status
Discontinued on
31 March 2015
End-of-service on
31 March 2015
XUSLBR5A1520 is replaced by:
Product
Qty
-
Characteristics
Main range of product Preventa Safety detectionseries name Basicproduct or component type Safety light curtain type 4device short name XUSLBoutput type 1 auxiliary output solid-state PNP2 safety outputs OSSD solid-state PNP (NO) (short-circuit protection)product specific application For hand protectionminimum object diameter for detection 30 mm[Sn] nominal sensing distance 8 m with Programming and Diagnostic Module (PDM)0.3…20 mheight protected 1520 mmnumber of beams 76Complementary detection system Transmitter-receiver systemresponse time 32 mskit composition 1 arc suppressor set(s)1 receiver(s)1 test rod(s)1 transmitter(s) 1 user guide with certificate of conformity on CD-ROM 2 sets of 2 brackets with fixings[EAA] effective aperture angle 2.5 ° at 3 mlight source GaAIAs LED, 880 nm[Us] rated supply voltage 24 V DC +/- 20 %[Ie] rated operational current 2 Acurrent consumption 450 mA no-load receiver1.8 A with maximum load receiver285 mA transmitteroutput current limits 100 mA for auxiliary output625 mA for safety outputs OSSDoutput voltage 24 Voutput circuit type DCswitching capacity in mA 50 mAelectrical connection 1 female connector M12 5 pins transmitter1 female connector M12 8 pins receiverfunction available Alignment aid by display of each light beam broken accessible by cabling aloneAuto/manual accessible via programming and diagnostic moduleAutomatic start accessible by cabling aloneAuxiliary output (PNP, status signalling) accessible by cabling aloneDisplay of operating modes and faults by LED and/or PDM accessible via programming and diagnostic moduleLED display of operating modes and faults accessible by cabling aloneLight beam coding (A or B) accessible via programming and diagnostic moduleMonitoring of external switching devices (EDM: External Device Monitoring) accessible via programming and diagnostic moduleProgramming+downloading of conf settings, via programming+diagnostic module(PDM) accessible via programming and diagnostic moduleSensing distance (short, long) accessible via programming and diagnostic moduleTest (MTS: Monitoring Test Signal) accessible by cabling alonemarking CEmaterial Aluminium: casing20 % fibre glass impregnated nylon: end capsfixing mode End bracketsnet weight 7.33 kgEnvironment standards Work equipment directive 2009/104/ECEN/IEC 61496-1EN/IEC 61496-1-2 for type 4 ESPEANSI B11:19-1990OSHA 1910-212Machinery directive 2006/42/ECEN/IEC 61496-2ANSI/RIA R15.06EMC 2004/108/ECOSHA 1910-217CROHS directive 2002/95/ECproduct certifications TÜVULCSAsafety level Can reach SIL 3 correctly wired conforming to IEC 61508Can reach category 4 correctly wired conforming to EN/ISO 13849-1Can reach PL = e correctly wired conforming to EN/ISO 13849-1Type 4 conforming to IEC 61496-1-2safety reliability data PFH = 4.9E-8 1/h conforming to IEC 61508 verified in worst case conf: 256 beams, 2 segments, mute 20 year(s)ambient air temperature for operation -10…55 °Cambient air temperature for storage -25…75 °Crelative humidity 0…95 % without condensationIP degree of protection IP65shock resistance 10 gn for 16 ms conforming to IEC 61496-1vibration resistance 0.35 +/- 0.05 mm (f= 10…55 Hz) conforming to IEC 61496-1Contractual warranty Warranty 18 months -
View more
Documents
Language- All Languages6
- English2
- French1
- German1
- Italian1
- Spanish1
User guideFormatSizeAdd to My DocumentsXUSLB/XUSLDM Safety Light Curtain (Version 00)DescriptionThe XUSLB/XUSLDM system is for use where personnel protection is required.Size pdfSize 3.6 MBDate 2/1/08DescriptionThe XUSLB/XUSLDM system is for use where personnel protection is required.End of Life InformationFormatSizeAdd to My DocumentsXUSLN..., XUSLP..., XUSLB... and XUSLD... Safety light curtains, Product End-of-Life Instructions (Version 1.0)Size pdfSize 137.6 KBDate 11/1/11 -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.